3, 4 - Wire electrical wall Receptacle types

Conduit connection plate is used for the installation of
power cord or conduit. For power cord, install it with
conduit connection plate as manufacturer supplied.
For conduit cord, remove the conduit connection plate
located below the rear of the drawer body and use the
conduit hole (1

1

/

8

”) instead of power cord hole (1

3

/

8

”).

(Refer to Figure 8.)

4

3

CONNECT RANGE CORD

The Rear Access cover must be removed. Loosen the
three screws with a screwdriver. The terminal block
will then be accessible.

4

FIGURE 3

FIGURE 4

Range rating, watts

Specified rating

of power-supply-
cord kit, amperes

120/240 volts

3-wire

8,750 - 16,500

16,501 - 22,500

120/208 volts

3-wire

7,801 - 12,500

12,501 - 18,500

40 or 50A

50

Diameter (inches) of Range

connection Opening

Conduit

1

1

/

8

1

1

/

8

Power cord

1

3

/

8

1

3

/

8

Specified power-supply-cord kit rating

Part 3

ELECTRICAL CONNECTIONS

ELECTRICAL CONNECTION
REQUIREMENTS

This appliance must be installed and grounded on a
branch circuit by a qualified technician in accordance
with the National Electrical code ANSI/NFPA NO. 70 -
latest edition.

All wiring should conform to Local and NEC. This
range requires a single-phase, 3 wire, A.C 120/208V or
120/240V 60Hz electrical system. Use only a 3-conductor
or a 4-conductor UL-listed range cord with closed-
loop terminals, open-end spade lugs with upturned
ends or similar terminations. Cord must have the
strain relief properly installed.

A range cord rated at 40 amps with 120/240 minimum
volt range is required. If a 50 amp range cord is used,
it should be marked for use with 1

3

8

” diameter

connection openings.

This appliance may be connected by means of conduit
or power cord. If conduit is being used, go to page 6
3 wire conduit connections or page 7 for 4 wire
conduit connections
.

WARNING

New branch-circuit installations (1996 NEC), mobile
homes, recreational vehicles, and installations
where local codes do not allow grounding through
neutral require a 4-conductor UL listed range cord
or 4 wire conduit connection.

4 Wire receptacle (14-50R)

3 Wire receptacle (10-50R)