Part 3 electrical connections, Wire connection: conduit, Wire connection – LG LRE30755S User Manual

Page 7

Advertising
background image

7

Part 3

ELECTRICAL CONNECTIONS

Third, connect the wires.
If bare wire is used, connect with adapter lugs as shown
in Figures 11 and 12.

1. Insert the end of each wire (L1, L2, Neutral) into the

each lug. Tighten the clamping screw.

2. Remove the 3 nuts from the terminal block and

retain them.

3. Attach the lug with white wire (Neutral) to the center

terminal block bolt.

4. Attach the lug with black wire (L2) to the left

terminal block bolt.

5. Attach the lug with red wire (L1) to the right terminal

block bolt.

6. Tighten 3 nuts (removed earlier) securely onto the

terminal block.

7. Go to page 8.

1. Follow the instructions under “Install the conduit

cord as follows” on page 6 to correctly install the
strain relief.
You must install the conduit with a strain
relief.

2. Cut the center portion of ground strap as

shown Figure 13.
Do not discard any screws.
If bare wire is used, connect with adapter lugs as
shown in Figures 11 and 13.

3. Insert the end of green wire (ground) from conduit

into the lug and tighten the clamping screw. Attach
the lug to the GND hole below terminal block with
ground screw (removed earlier).

4. Insert the end of each wire (L1, L2, Neutral) into

each separate lug. Tighten the clamping screw.

5. Remove the 3 nuts from the terminal block.

Remove the ground screw and retain them.

6. Attach the lug with white wire (Neutral) to the

center terminal block bolt.

7. Attach the lug with black wire (L2) to the left

terminal block bolt.

8. Attach the lug with red wire (L1) to the right

terminal block bolt.

9. Tighten 3 nuts (removed earlier) securely into the

terminal block.

10. Go to page 8.

L2

L1

N

G

L2

L1

N

FIGURE 11

Reinstall the

Conduit connection plate

L2

L1

N

G

L2

L1

N

L2

L1

N

FIGURE 12

3-wire connection

L2

L1

N

L2

L1

N

G

G

L2

L1

N

FIGURE 13

4-wire connection

4-wire connection: conduit

BARE WIRE TORQUE SPECIFICATIONS
LUG ATTACHED TO TERMINAL BLOCK

- 20 IN-LB

WIRE AWG

10-14

8

4-6

TORQUE

20 IN-LB

25 IN-LB

35 IN-LB

Advertising