Part 3

ELECTRICAL CONNECTIONS

1. Remove the 3 nuts from the terminal block.

(Refer to Figure 7.)
Remove the ground screw and washer retain them.

2. Cut the center portion of ground strap as

shown Figure 7.
Do not discard any screws.

3. Attach the ground wire with the ground screw and

washer.

4. Attach the 3 wires (L1, Neutral, L2) to the correct

terminal block bolts. Be certain that the center wire
(white/neutral) is connected to the center position of
the terminal block. Tighten the 3 nuts securely onto
the terminal block.

5. Go to page 8.

Install the conduit as follows:

Remove the Conduit connection plate from the rear of
drawer body and rotate it as shown in Figure 8. The
conduit hole (1

1

/

8

”) must be used.

First, prepare conduit cord as shown in Figure 9.

Second, install conduit cord as shown in Figure 10.

For conduit installations, after purchasing a strain
relief, insert it in the conduit hole (1

1

/

8

”). Then install

the conduit cord through the body of strain relief and
fasten the strain relief with its ring. Reinstall the
bracket.

FIGURE 9

FIGURE 8

FIGURE 10

Remove the Conduit connection plate

Assemble the

strain relief hole

3-wire connection: conduit

or

3 wire

4 wire