Important – Lennox Hearth Cambria User Manual

Page 13

Advertising
background image

1. Combustible material must be installed flush

with the fireplace. It may not project in front

of and on the fireplace (i.e. the steel facade

of the fireplace) (see Figure 19).

2. Non-combustible materials such as brick,

stone or ceramic tile may project in front

of and onto the fireplace facing (see Figure

20).

MANTEL AND FACING

The mantel must be installed at least 59”

(1500 mm) above the base of the fireplace

(see Figure 18).

IMPORTANT

The facade must be removable

once installed. The facade is

designed to overlap any facing

material installed on the front of

the fireplace. If thicker material

is installed, use the facade as a

template and make sure it can be

easily removed for servicing.

FACING

1

3

4

5

6

2

1

2

7

3

4

1. Fireplace

2. Front of fireplace

3. Wood frame (2” x 3” min)

4. Drywall

5. Tiles

6. Rock board or other

7. Brick

Fireplace Frame Section

(Top View)

Figure 17

Optional Fireplace Blower (UZY5)

A heat activated blower is sold as an option. It is
designed to be located in the back of the fireplace
and increase the air flow around the firebox. It
uses regular 120V and must be connected to the
main electrical circuit by a qualified electrician.
An electrical box must be installed outside the
fireplace.

WARNING: Because of the fireplace size and
obstructive air venting, we don’t recommend
the installation of the blower unless the gravity
ducting is installed on the fireplace.

If you wish to adjust the blower speed, an optional
variable speed control (VRUW) can be installed
in line with the wiring. Again, use a qualified
electrician for installation.

To install the blower,

1- Remove the refractory bricks and the and-

iron.

2- Remove the metal plates covering the bottom

and back of the hearth firebox.

3- Disconnect the main electric cable from the

blowers by unplugging its two quick connec-
tors.

4- Remove the knock-out in the front right side

of the fireplace outer casing.

5- Install a metallic wire protector and slide the

blower main electrical cable from the outside
to the inside of the unit.

6- Install the two blowers in the back of the

fireplace through the holes in the back.
Warning: Make sure there are no contact
between the blowers and the door slider.

7- Reconnect the main cable quick connectors

and stick (magnet) the heat activate switch
under the right side of the firebox. Using
aluminum tape, make sure no wiring touch
the firebox by taping it to the bottom of the
fireplace panel.

8- Install all plates, bricks and andiron.
9- Connect the blower plug into the electrical

box located outside the fireplace.

Flameproof Facing

Figure 19

Figure 18

}}

}

Drywall

2” x 3” Min.

Spacer

Mantel

59”

u

u

Non-Combustible

Panel Only

v

Flameproof Facing

v

Mantel and Facing

(Side View)

Drywall

2” X 3” Min.

Spacer

Metal Mesh Screwed in

Board and Fireplace

Non-Combustible Panel Only

Figure 20

Only non-combustible mate-

rial should be superposed or

projecting over the front of the

fireplace.

59”

Min.

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

13