Warning, Avertissement – Lennox International Inc. MERIT PLUS MPB3530CNM-B User Manual

Page 2

Advertising
background image

2

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

LENNOX HEARTH PRODUCTS • MERIT PLUS

®

B-VENT GAS FIREPLACES (MPB33/35/40/45) • INSTALLATION INSTRUCTIONS

PACKAGING

The assembled vented gas fi replace is
packaged with:

• (1 set) Logs (packaged in a carton inside

the fi rebox).

• (1 bag) Volcanic Stone (included in the

fi rebox or bottom compartment).

• (1 bag) Glowing Embers (in bottom

compartment).

• Literature Kit (envelope in bottom com-

partment containing Care and Operation

Instructions, Installation Instructions,

Safety-In-Operation Warning Labels,

Warranty).

• (1) Hood (behind the top louver assembly).

INTRODUCTION

The Millivolt appliances have a millivolt gas
control valve with piezo ignition system. If
any optional accessories that will require
electrical power are to be installed, the
electrical power must be provided at the time
of appliance installation.

The Electronic appliances are designed
to operate on natural or propane gas. An
electronic intermittent pilot ignition system
provides safe, effi cient operation. External
electrical power is required to operate these
units. In the event of a power outage, four (4)
"AA" batteries (in battery holder) provide
backup power for appliance operation
(excluding [optional] blower).

APPROVED VENT COMPONENTS
These vented gas fi replaces are designed for
residential applications. They must be installed
with approved Type-B, double wall vent pipe
systems and a listed vent termination routed to
the outside atmosphere. Use only the proper
size listed below.

REQUIRED PIPE DIAMETER:
MPB33 series:
Requires 4 in. (102 mm)
MPB35 series: Requires 5 in. (127 mm)
MPB40 series: Requires 5 in. (127 mm)
MPB45 series: Requires 6 in. (152 mm)

WARNING

B-Vent appliances are not
designed to operate in negatively
pressured environments (pres-
sure within the home is less than
pressures outside). Signifi cant
negatively pressured environ-
ments caused by weather, home
design, or other devices may
impact the operation of these
appliances. Negative pres-
sures may result in poor fl ame
appearance, sooting, damage to
property and/or severe personal
injury. Do not operate these
appliances in negatively pres-
sured environments.

TABLE OF CONTENTS

Packaging .................................................... 2

Introduction ................................................. 2

General Information ..................................... 2

Requirements for the

Commonwealth of Massachusetts ............ 4

Cold Climate Insulation ................................ 4

Manufactured Housing ................................. 4

Location ........................................................5

Vent Termination Clearances ....................... 5

Appliance and Vent Clearances .................... 6

Pre-Installation Steps ................................... 7

Typical Installation Sequence ...................... 7

Detailed Installation Steps ............................ 7

Step 1. Framing ............................................ 7

Framing Specifi cations ................................ 8

Fireplace Specifi cations .............................. 9

Step 2. Routing Gas Line ............................. 9

Step 3. Installing Vent System ................... 10

Step 4. Field Wiring ................................... 11

Step 5. Wiring Optional

Forced Air Blower Kit .................... 12

Step 6. Connecting Gas Line ..................... 12

Step 7. Installing Optional Outside Air Kit ..13

Step 8. Verifying Appliance Operation ........... 14

Step 9. Installing Volcanic Stone, Glowing

Embers, and Logs ........................ 14

Step 10. Removing and

Installing the Glass Door ............. 19

Step 11. Burner Adjustments ..................... 19

Step 12. Testing Vent Operation ..................21

Step 13. Hood Installation .......................... 21

Step 14. Finishing Requirements ............... 21

Step 15. Attaching Safety-in-Operation
Warnings ............................ 22

Gas Conversion Kits ......................... 23

Children and adults should be alerted to
the hazards of high surface temperature
and should stay away to avoid burns or
clothing ignition.

Les enfants et les adultes devraient
être informés des dangers que posent
les températures de surface élevées
et se tenir à distance afi n d’éviter des
brûlures ou que leurs vêtements ne
s’enfl amment.

DO NOT ATTEMPT TO ALTER OR MODIFY
THE CONSTRUCTION OF THE APPLIANCE
OR ITS COMPONENTS. ANY MODIFICATION
OR ALTERATION MAY VOID THE WAR-
RANTY, CERTIFICATION AND LISTINGS OF
THIS UNIT.

WARNING

Young children should be care-
fully supervised when they are
in the same room as the appli-
ance. Toddlers, young children
and others may be susceptible
to accidental contact burns. A
physical barrier is recommended
if there are at risk individuals in
the house. To restrict access to
a fi replace or stove, install an
adjustable safety gate to keep
toddlers, young children and
other at risk individuals out of
the room and away from hot
surfaces.

AVERTISSEMENT

Les jeunes enfants devraient être
surveillés étroitement lorsqu’ils
se trouvent dans la même pièce
que l’appareil. Les tout petits,
les jeunes enfants ou les adultes
peuvent subir des brûlures s’ils
viennent en contact avec la sur-
face chaude. Il est recommandé
d’installer une barrière physique
si des personnes à risques habi-
tent la maison. Pour empêcher
l’accès à un foyer ou à un poêle,
installez une barrière de sécu-
rité; cette mesure empêchera les
tout petits, les jeunes enfants et
toute autre personne à risque
d’avoir accès à la pièce et aux
surfaces chaudes.

GENERAL INFORMATION

Advertising