Application:

The Ravelle™ 42 gas fireplace, has been tested and listed as a direct
vent heater system by OMNI-Test Laboratories, Portland, Oregon. and
is recommended for use with Security™ Secure Vent™ pipe.

IMPORTANT:

• Read all instructions carefully before starting the installation.

Failure to follow these instructions may create a fire or other

safety hazard and will void the warranty. Be sure to check for

specific clearances to combustible requirements on Page 7.

Do not extend the venting system vertically or horizontally in

excess of the distance prescribed on Page 19. Consult your

local building codes before beginning the installation.

Always maintain the proper air spaces (see Page 7) between

the vent pipe and nearby combustibles to prevent a fire hazard.

Do not fill air spaces with insulation. Be sure to check the

vent termination clearance requirements from decks, windows,

soffits, gas regulators, air supply inlets and public walkways,

as specified in these installation instructions on Page 20 and

local building codes.

This gas appliance and vent system must be vented directly to

the outside of the building and never be attached to a chimney

serving a separate solid fuel or gas-burning appliance. Each

direct vent gas appliance must use its own separate vent system.

Common vent systems are prohibited.

• The Ravelle 42 gas fireplace is recommended for use

with Security Secure Vent pipe. The appliances and vent

manufacturers warranties will be voided and serious fire, health,

or other safety hazards may result from any of the following

actions:

• Installation of any damaged direct vent component.
• Unauthorized modification of the direct vent system.
• Installation of any vent component part not approved or

manufactured by the approved vent manufacturer.

• Installation other than as instructed by Lennox Hearth

Products and vent manufacturers instructions.

Vent Parts List

Direct vent pipe Security™ Secure Vent™* may be used with the Ravelle
42 gas fireplace. Please see the lists below to verify the components avail-
able from each direct vent pipe manufacturer. Snorkel terminations are
available for applications which may require vertical rise on the building
exterior. The components listed below come in a galvanized finish. Most
of the components are also available in a painted black finish. Add a “B”
to the end of the part number when ordering if a black part is desired.

Security™ Secure Vent 6-5/8”x 4” Pipe

Part Number

Description

SV4L6

6” Pipe Length

SV4L12

12” Pipe Length

SV4L24

24” Pipe Length

SV4L36

36” Pipe Length

SV4L48

48” Pipe Length

SV4LA

6” Pipe, Adjustable

SV4LA12

12” Pipe, Adjustable

SV4FA

Flashing, 1/12 to 176/12 Roof Pitch

SV4FB

Flashing, 8/12 to 12/12 Roof Pitch

SV4RSM

Wall Radiation Shield

SV4E46

45° Elbow

SV4E90

90° Elbow

SV4VS

Vinyl Shield Protector

SV4FC

Storm Collar

SV4CGV

Vertical Termination Cap

SV4BF

Firestop

SV4CHC

Horizontal Termination Cap

SV4STC36

Snorkel Termination (36”) Cap

SV4STC14

Snorkel Termination (14”) Cap

SV4BM

Wall Band

Simpson DuraVent 6-5/8”x 4” GS Pipe

Part Number

Description

908

6” Pipe Length

907

9” Pipe Length

906

12” Pipe Length

904

24” Pipe Length

903

36” Pipe Length

902

48” Pipe Length

911

11” to 14-5/8” Pipe, Adjustable

912

12” to 17” Pipe, Adjustable

917

17” to 24” Pipe, Adjustable

942

Wall Thimble

943

Flashing, 0/12 to 6/12 Roof Pitch

943S

Flashing, 7/12 to 12/12 Roof Pitch

945

45° Elbow

950

Vinyl Siding Standoff

953

Storm Collar

963

Ceiling Firestop

980

Vertical Termination

981

Snorkel Termination (36”)

982

Snorkel Termination (14”)

984

Horizontal Square Termination (High Wind)

988

Wall Strap

991

Vertical Termination (High Wind)

14

VENT INSTALLATION

Advertising