For altitudes above 2,000 feet (In Canada 4,500 FT/1370 M),the orifice

should be de-rated by 4% for every 1,000 feet to maintain the proper

ratio of gas to air. Improper orifice sizing may result in damage and

unsafe conditions. Changing the orifice should only be done by a quali-

fied service technician. Contact your Lennox Hearth Products dealer for

proper orifice sizes.

4

ORIFICE SIZE/ALTITUDE ADJUSTMENT

Since there are always several potential sources of fire in any home, we

recommend installing smoke detectors. If possible, install the smoke

detector in a hallway adjacent to the room (to reduce the possibility of

occasional false activation from the heat produced by the appliance). If

your local code requires a smoke detector be installed within the same

room, you must follow the requirements of your local code. Check with

your local building department for requirements in your area.

SMOKE DETECTORS

• Must conform with all local, state and national installation codes.

In the absence of local codes, the installation must conform with

National Fuel Gas Code ANSI Z223.1 - latest edition, also known

as NFPA 54 (In Canada, the current CAN/CSA B149.1 installation

code). Refer to the National Fuel Gas Code and local zoning and

code authorities for details on installation requirements.

• Mobile home installations must conform with the Mobile Home

Construction and Safety Standard, Title 24 CFR, Part 3280 (in Canada

CAN/CSA Z240 MH), or, when such a standard is not applicable,

the Standard for Mobile Home Installations, ANSI A225.1 - latest

edition.

• Must be vented directly to the outside in accordance with the latest

edition of the National Fuel Gas Code and must never be attached

to a chimney serving a separate solid fuel burning appliance.

• Has been certified for use with either natural gas or propane.

• Is not for use with solid fuels.

• Is approved for sitting rooms and/or bedrooms.

THE RAVELLE™ 4 FIREPLACE