Impinger II – Advantage Service Manual - Domestic

10

Power Supply

If there is sufficient micro-amp current, but the flame
will not stay lit, check for proper polarity of the 120
VAC power supply.

Ignition Control

If there is sufficient micro-amp current, and the 120
VAC polarity is correct, but the flame will not stay lit,
replace ignition control.

NOTE: Check for proper ground connection on
ignition control.

NOTE: Flame should be lit at
this time.

Low flame is on,
but no main flame

Temperature Control

Check for 120 VAC at terminal #7
to neutral on temperature control. If no voltage,
trace voltage back through centrifugal switch and hi-
limit. Turn the temperature adjustment knob to
maximum temperature position and check for 120
VAC at the load terminal #8 and neutral. If 120 VAC
is present and unit is not heating, refer to
"Temperature Solenoid Valve" for next check. If 120
VAC is not present, proceed.

Thermocouple Probe

WITH POWER ON AND THERMOCOUPLE LEADS
ATTACHED TO THE TEMPERATURE CONTROL
BOARD: Measure the D.C. millivolt output of these
leads. Refer to thermocouple chart in Section D for
proper readings. If these readings are not achieved,
replace the thermocouple.

Temperature Set

Disconnect the potentiometer leads

Potentiometer

from the board. Place ohm meter test leads on the
blue and green pot leads. Reading should be 1 K
ohms. Place meter leads across the blue and purple
pot leads and rotate knob from high to low. Repeat
on green and purple leads. Check for even rise and
fall of ohms reading to insure that there are no open
or dead spots in the potentiometer. Check each
lead to ground for shorts. Replace pot if it does not
meet the above test.

Temperature Solenoid

If 120 VAC is present on the

Valve

temperature control board at load terminal #8 to
neutral, check for voltage at temperature regulation
valve. If voltage is present, listen for valve to open
and close. Also check for opens or shorts in the coil.
Replace as necessary.

Intermittent Heating

Thermal/Overload of Main Fan
and Burner Blower Motors

The main fan motor and the burner blower motor are
equipped with internal thermal protection and will
cease to operate if over heating occurs. As the
motors overheat and then cool, this will cause the
units to cycle on and off intermittently. This may be
caused by improper ventilation or preventive
maintenance. Also, most of the problems listed
under "Oven will not heat" can cause intermittent
failure.

Conveyor will not run

Voltage Supply

Check incoming voltage supply at line 1 to neutral.
There should be a voltage reading of 120 VAC. If
not present, check breakers.

10 Amp Fuse

Check and/or replace.

Fuseholder

Check and/or replace.

Fan Switch

See procedure for checking on Page 10.