NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

LENNOX HEARTH PRODUCTS • MONTEBELLO

®

DV GAS FIREPLACES

(LSM40/45MN-2, LSM40/45MP-2, LSM40/45EN-2)

• CARE AND OPERATION INSTRUCTIONS

The following paragraphs address burner

adjustment concerns and procedures.

When lit for the first time, this appliance will emit

a slight odor for an hour or two. This is due to

the “burn-in” of internal paints and lubricants

used in the manufacturing process.

Adjustment

To adjust the flame, move the adjustment air

shutter (located on the lower venturi) back or

forward to increase or reduce the air shutter

opening, respectively. Position the air shut-

ter to the factory setting as shown in Figure

15. Allow the burner to operate for at least 15

minutes. Observe the flame continuously. If it

appears weak or sooty as previously described,

adjust the air shutter until the flame appearance

is as desired.

Propane models may exhibit a flame pattern

that may candle or appear stringy. If this is

problematic or persists as the appliance is

continually operated, adjust the air shutter

open as described in the previous paragraphs.

Operate the appliance for a period of time as the

effect diminishes, ensuring that the appliance

does not develop sooty flames.

When satisfied that the appliance operates

properly, proceed to finish the installation. Leave

the control knob in “ON” position and turn the

remote switch “OFF.”

WARNING

Air shutter adjustment should

only be performed by a quali-

fied professional service

technician.

Ensure that the front glass

door assembly is in place and

sealed After adjustment.

Figure 15

Main Burner Factory Air Shutter

Opening Setting - Inches (millimeter)

Model

Nat.Gas

Propane Gas

LSM40-2

1/16 (1.59)

9/32 (7.14)

LSM45-2

1/16 (1.59)

9/32 (7.14)

CAUTION

Soot will be produced if the air

shutter is closed too much. Any

damage due to carboning result-

ing from improperly setting the

air shutter is not covered under

the warranty.

Electronic Appliance Checkout

To light the burner, refer to the lighting instruc-

tions on Page 20. Ensure the igniter lights the

pilot. The pilot flame should engulf the flame

sensor as shown in Figure 17.

Millivolt Appliance Checkout

The pilot flame should be steady, not lifting

or floating. Flame should be blue in color with

traces of orange at the outer edge.

The top 3/8" (10 mm) at the pilot generator

(thermopile) and the top 1/8" minimum (tip)

of the quick drop out thermocouple should be

engulfed in the pilot flame. The flame should

project 1" (25 mm) beyond the hood at all three

ports (see Figure 16).

To light the burner, refer to the lighting instruc-

tions on Page 18.

Figure 17

Pilot

Nozzels

ELECTRONIC PILOT ASSEMBLY

Proper Pilot Flame Appearance

Flame

Sensor

Pilot Hood

Igniter

Rod

Figure 16

Thermocouple

Thermopile

Pilot

Nozzels

SIT MILLIVOLT PILOT ASSEMBLY

Igniter Rod

Pilot Hood

Proper Pilot Flame Appearance

3/8" Min.

(9 mm)

Air Shutter

Opening

Venturi

Orifice

Gas Valve

Burner

Venturi

Burner Air Shutter Adjustment Procedure

Advertising