Lennox Hearth 875027M User Manual

Page 22

Advertising
background image

22

LENNOX HEARTH PRODUCTS • MONTEBELLO

®

DV GAS FIREPLACES

(LSM40/45MN-2, LSM40/45MP-2, LSM40/45EN-2)

• CARE AND OPERATION INSTRUCTIONS

Annually (Before the onset of the Burning Season)

MAINTENANCE TASK

ACCOMPLISHING PERSON

PROCEDURE

Inspect/Clean Burner, Logs
and Controls

Qualified Service Technician

Inspect valve and ensure it is properly operating. Check piping for
leaks. Vacuum the control compartment, fireplace logs and burner area.

Check Flame Patterns and Flame Height Qualified Service Technician

Refer to Figure 13 (LSM40-2) or Figure 14 (LSM45-2) on Page 13 and
verify the flame pattern and height displayed by the appliance conforms
to the picture. Flames must not impinge on the logs. Ensure flames
are steady (not lifting or floating).

Inspect/Clean Pilot and Burner

Qualified Service Technician

Refer to Figure 16 (Millivolt) or Figure 17 (Electronic) on Page 14.
Remove any surface build-up on pilot and burner assembly. Wipe the
pilot nozzles, igniter/flame rod and hood. Ensure the pilot flame engulfs
the flame sensor as shown.

Check Vent System

Qualified Service Technician

Inspect the vent system at the top and at the base (within the firebox)
for signs of blockage or obstruction. Look for any signs of dislocation
or deterioration of the vent components. Note: Excessive condensation
can cause corrosion of caps, pipe & fittings (excessive condensation can
be caused by long lateral runs, too many elbows and/or exterior portions
of the system being exposed to cold weather). Also inspect wall straps
or plumbers's tape to ensure it is secure and in place.

Appliance Checkout

Qualified Service Technician

Perform the appropriate appliance checkout procedure detailed in this
manual.

Replace Glowing Embers

Homeowner/Qualified Service
Technician

Remove old ember materials (rockwool) and vacuum the ember place-
ment area. Place new embers per instructions on Page 11.

Periodically (After the Burning Season)

MAINTENANCE TASK

ACCOMPLISHING PERSON

PROCEDURE

Clean Firebox Interior

Homeowner

Carefully remove logs, rockwool, volcanic stone and vermiculite. Vacuum
out interior of the firebox. Clean firebox walls and log grate. Replace
logs, rockwool, vermiculite and volcanic stone as detailed in this manual.

Check Flame Patterns and Flame Height Homeowner

Refer to Figures 13 and 14 on Page 13 and verify the flame pattern and
height displayed by the appliance conforms to the picture. Flames must
not impinge on the logs.

Check Vent System

Homeowner

Inspect the vent system at the top and at the base (within the firebox)
for signs of blockage or obstruction. Look for any signs of dislocation
of the vent components.

Clean Front Glass Enclosure Panel

Homeowner

Clean as necessary following the directions provided in this manual. DO
NOT TOUCH OR ATTEMPT TO CLEAN GLASS WHILE HOT
.

MAINTENANCE SCHEDULE

Turn off gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.

Advertising