Wiring diagrams, Product reference information, Warranty – Lennox Hearth ELITE 875022M User Manual

Page 17: Replacement parts

Advertising
background image

17

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

ATTENTION: AU MOMENT DE L'ENTRETIEN DES COMMANDES, ÉTIQUETEZ

TOUS LES FILS AVANT DE LES DÉBRANCHER. DES ERREURS DE CÁBLAGE

PEU-VENT ENTRAÎNER UN FONCTIONNEMENT INADÉQUAT ET DANGEREUX.

LENNOX HEARTH PRODUCTS

1508 Elm Hill Pike, Suite 108

Nashville, TN 37210

visit us at www.Lennox.com

1-800-9-LENNOX

PRODUCT REFERENCE INFORMATION

We recommend that you record the following

important information about your fireplace.

Please call Lennox Hearth Products for the

phone number of your nearest Lennox Hearth

Products dealer who will answer your questions

or address your concerns.

Your Fireplace's Model Number ___________________________________________

Your Fireplace's Serial Number ___________________________________________

The Date On Which Your Fireplace Was Installed ______________________________

The Type of Gas Your Fireplace Uses _______________________________________

Your Dealer's Name ___________________________________________________

Parts will be shipped at prevailing prices at

time of order.

When ordering repair parts, always give the

following information:

1. The model number of the appliance.

2. The serial number of the appliance.

3. The part number.

4. The description of the part.

5. The quantity required.

6. The installation date of the appliance.

If you encounter any problems or have any

questions concerning the installation or ap-

plication of this system, please contact your

dealer or distributor.

WARRANTY

Your gas appliance is covered by a twenty year

limited warranty. You will find a copy of the war-

ranty accompanying this manual. Please read

the warranty to be familiar with its coverage.

Retain this manual. File it with your other docu-

ments for future reference.

REPLACEMENT PARTS

A complete parts list is found at the end of

this manual. Use only parts supplied from the

manufacturer.

With proper care and maintenance, your appli-

ance will provide many years of enjoyment. If

you should experience any problem, first refer

to the troubleshooting guide in this manual. If

problem persists, contact your Lennox Hearth

Products dealer or distributor.

Normally, all parts should be ordered through your

Lennox Hearth Products distributor or dealer.

Thermopile

TH

TP

TH

TP

Millivolt Wiring Diagram

If any of the original wire as supplied must be replaced,

it must be replaced with

Type AWM 105° C – 18 GA. wire.

*OR OPTIONAL WALL-MOUNTED ON/OFF SWITCH

OR OPTIONAL THERMOSTAT

OR OPTIONAL REMOTE CONTROL RECEIVER

Factory Wired

Field Wired

Schematic Representation Only

APPLIANCE-MOUNTED ON/OFF SWITCH

*Turn the appliance-mounted ON/OFF burner control switch

to the OFF position if an optional

control switch is installed.

1. If any of the original wire as supplied must be replaced,

1.

it must be replaced with

Type AWM 105

°C – 18 GA. wire.

2. 120V, 60Hz – Less than 3 amps.

BK

Transf.

120 V.

24 V

Factory Wired

Field Wired

BL

Electronic Wiring Diagram (Honeywell)

Showing the Blower Wiring for the Optional

FBK-250 Kits

R

WH

BL

W

Gas Valve

B

R

IGNITE

R

BK

Schematic Representation Only

*ON/OFF Switch (Integral

with Gas Valve)

Optional

FBK-250

Module

*Leave the ON/OFF switch, which is integral

with the gas valve, in the ON position.

G

OPTIONAL APPLIANCE-MOUNTED ON/OFF SWITCH

OR OPTIONAL WALL SWITCH OR OPTIONAL THERMOSTAT

OR OPTIONAL REMOTE RECEIVER

PILOT

ASSEMBLY

OPT

BLOWER

junction Box

White

Green

Red

Black

Neutral

Side of

Receptacle

Tab Intact

Green

Ground

Screw

Hot

Side of

Receptacle

Tab

Broken

Optional

Accessory

Switch

120 VAC - Black

n

e

e

r

G

-

d

n

u

o

r

G

e

ti

h

W

-

l

a

rt

u

e

N

1. If any of the original wire as supplied must be replaced,

1.

it must be replaced with

Type AWM 105

°C – 18 GA. wire.

2. 120V, 60Hz – Less than 3 amps.

BK

Transf.

120 V.

24 V

Factory Wired

Field Wired

BL

Electronic Wiring Diagram (Honeywell)

Showing the Blower Wiring for the Optional

FBK-100 and FBK-200 Kits

R

W

BL

W

Gas Valve

B

R

IGNITE

R

BK

*Blower speed control switch is provided in FBK200 blower kit.

Schematic Representation Only

**ON/OFF Switch (Integral

with Gas Valve)

**Leave the ON/OFF switch, which is integral

with the gas valve, in the ON position.

OPTIONAL APPLIANCE-MOUNTED ON/OFF SWITCH

OR OPTIONAL WALL SWITCH

OR OPTIONAL THERMOSTAT

OR OPTIONAL REMOTE RECEIVER

G

OPT

BLOWER

PILOT

ASSEMBLY

junction Box

White

Green

Red

Black

Neutral

Side of

Receptacle

Tab Intact

Green

Ground

Screw

Hot

Side of

Receptacle

Tab

Broken

120 VAC - Black

n

e

e

r

G

-

d

n

u

o

r

G

Optional

Accessory

Switch

e

ti

h

W

-

l

a

rt

u

e

N

WIRING DIAGRAMS

Wiring diagrams are provided here for reference

purposes only. This information is also provided

on schematics attached directly to the appliance

on a pullout panel located within the control

compartment.

CAUTION: LABEL ALL WIRES PRIOR TO

DISCONNECTION WHEN SERVICING

CONTROLS. WIRING ERRORS CAN

CAUSE IMPROPER AND DANGEROUS

APPLIANCE OPERATION.

Advertising