NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Figure 3

Honeywell Electronic

Gas Valve

Figure 2

Note: The piezo ignitor is located on the modesty panel - refer to Figure 1.

Variable Flame Height Adjustment

( Millivolt Appliances only)

1. All Millivolt appliances are equipped with

a variable gas control valve. Flame height for

these models may be adjusted through a range

between fixed low and high settings, alternately,

while the appliance is in operation.

Adjust the flame height as desired after lighting

the appliance by rotating the variable adjustment

control knob located on the front of the valve

(refer to Figure 2). (An extension is provided to

this knob so that the adjustment may be made

at the modesty panel.)

2. When lit for the first time, this appliance will

emit a slight odor for an hour or two. This is due

to the “burn-in” of internal paints and lubricants

used in the manufacturing process.

3. Keep lower control compartment clean by

vacuuming or brushing at least twice a year.

More frequent cleaning may be required due to

excessive lint from carpeting, bedding materials,

etc. It is important that control compartments,

burners and circulating air passageways of the

appliance be kept clean and clear of obstruction

of venting and combustion air.

4. Always turn off gas to the pilot (millivolt

appliances) before cleaning. Before re-lighting,

refer to the lighting instructions in this manual.

Instructions are also found on a pull-out panel

located on the floor of the appliance.

5. Always keep the appliance area clear and

free from combustible materials, gasoline and

other flammable liquids.

6. Remember, Millivolt appliances have a contin-

uous burning pilot flame. Exercise caution when

using products with combustible vapors.

HI

LO W

TPTH

TP

TH

PILO

T

PIL

OT

ON

it

OFF

Variable Flame Height Adjustment

Manifold Pressure Port

Inlet Pressure Port

Main Gas

Control Knob

IN

OUT

SIT Millivolt Gas Valve

ON/OFF Switch

Electronic

Gas Control

Valve

Inlet

Pressure

Port

Manifold Pressure Port

OFF

IN

P

S

I

ON

CONTROL

IG

N

IT

ER

Millivolt Appliances -

To light millivolt appliances refer to the detailed

lighting instructions found on page 26 (English)

and page 27 (French). Millivolt appliance

lighting instructions may also be found on the

pull out lighting instruction labels attached to

the gas control valve.

Millivolt appliances are fitted with an ON/OFF

Rocker Switch for appliance ON/OFF control.

Refer to Figure 1 for its location. Once the

pilot is lighted, the ON/OFF rocker switch will

control the appliance ON/OFF operation. To

operate: Toggle the switch between its ON and

OFF positions.

If your millivolt appliance is equipped with an

optional remote wall switch or remote control

kit and the pilot is lit, the appliance main burner

may be turned on and off with the wall switch

or remote control.

Electronic Appliances -

To light electronic appliances refer to the

detailed lighting instructions found in both

English and French on pages 28 and 29 of

these instructions respectively. Electronic

appliance lighting instructions may also be

found on the pull out lighting instruction labels

attached to the gas control valve. Electronic

appliances are fitted with an ON/OFF Rocker

Switch for appliance ON/OFF control. Refer to

Figure 1 for its location.

Once the pilot is lighted, the ON/OFF rocker

switch will control the appliance ON/OFF opera-

tion. To operate: Toggle the switch between its

ON and OFF positions.

If your electronic appliance is equipped with an

optional remote wall switch or remote control kit

the appliance main burner may be turned on and

off with the wall switch or remote control.