Lennox Hearth DIRECT-VENT SYMMETRY SERIES SYM-35N User Manual

Page 24

Advertising
background image

24

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Periodically (After the Burning Season)

Maintenance Task

Accomplishing Person

Procedure

Cleaning Firebox Interior

Check Flame Patterns and Flame Height

Checking Vent System

Cleaning Front Glass Enclosure Panel

Homeowner

Homeowner

Homeowner

Homeowner

Carefully remove logs, rockwool and decorative

volcanic stone and vermiculite. Vacuum out

interior of the firebox. Clean firebox walls and

log grate. Replace logs, Rockwool and volcanic

stone as detailed in this manual.

Maintenance Task

Accomplishing Person

Procedure

Inspecting/Cleaning Burner, Logs

and Controls

Check Flame Patterns and Flame Height

Inspecting/Cleaning Pilot and Burner

Checking Vent System

Appliance Checkout

Replacing Rockwool Ember Materials

Qualified Service Technician

Qualified Service Technician

Qualified Service Technician

Qualified Service Technician

Qualified Service Technician

Homeowner/Qualified Services Technician

Inspect valve and ensure it is properly op-

erating. Check piping for leaks. Vacuum

the control compartment, fireplace logs and

burner area.

Refer to Figures 14 (SYM-35), 15 (SYM-40)

or 16 (SYM-45) on page 17 and verify the

flame pattern and height displayed by the

appliance conforms to the picture. Flames

must not impinge on the logs.

Remove any surface build-up on pilot and

burner assembly. Wipe the pilot nozzles,

ignitor/flame rod and hood. Ensure the pilot

flame engulfs the flame sensor as shown.

Inspect the vent system at the top and at the

base (within the firebox) for signs of blockage

or obstruction. Look for any signs of disloca-

tion of the vent components.

Perform the appropriate appliance checkout

procedure detailed in this manual.

Remove old ember materials and vacuum the

rockwool placement area. Place new rockwool

as described in this document.

Maintenance Schedule

Annually (Before the onset of the Burning Season)

Clean as necessary following the directions

provided in this manual. DO NOT TOUCH OR

ATTEMPT TO CLEAN GLASS WHILE HOT.

Inspect the vent system at the top and at the

base (within the firebox) for signs of blockage

or obstruction. Look for any signs of disloca-

tion of the vent components.

Refer to Refer to Figures 14 (SYM-35), 15

(SYM-40) or 16 (SYM-45) on page 17 and

verify the flame pattern and height displayed

by the appliance conforms to the picture.

Flames must not impinge on the logs.

Advertising