NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Orifice Sizes - Sea Level to High Altitude

(All Models): These appliances are tested and

approved for installations at elevations of 0-4500

feet (0-1372 meters) above sea level using the

standard burner orifice sizes (marked with an

"*" in Table 4).

For higher elevations, contact your gas supplier

or qualified service technician.

The appliance must have been installed

according to the regulations of the local

authorities having jurisdiction and, in the

USA, the National Fuel Gas Code NFPA 54 /

ANSI Z223.1 - latest edition or, in Canada, the

CAN/CSA-B149.1- latest edition.

Deration -

At higher elevations, the amount of BTU fuel

value delivered must be reduced by either

using gas that has been derated by the gas

company or by changing the burner orifice to a

smaller size as regulated by the local authorities

having jurisdiction and by the (USA) National

Fuel Gas Code NFPA 54/ANSI Z223.1 - latest

edition or, in Canada, the CAN/CSA-B149.1

- latest edition.

Burn-in Period

During the first few fires of this appliance there

will be some odor due to the curing of the

paint and burning off of lubricants used in the

manufacturing process. Depending on your

use, the burn-in period may take a few hours

or a few days.

KEEP YOUR HOUSE WELL VENTILATED

DURING THE CURING PROCESS. THE ODOR

AND HAZE EMITTED DURING THE CURING

PROCESS CAN BE QUITE NOTICEABLE AND

MAY SET OFF A SMOKE DETECTOR. IT IS

RECOMMENDED THAT THE BLOWER NOT BE

OPERATED DURING THE BURN IN PERIOD.

If an optional blower is installed, Do Not turn

it on during the Burn-In period.

A white film may develop on the glass front

during the first few fires as part of the curing

process. The glass should be kept clean during

the first two weeks of use to prevent the film from

baking on (making it very difficult to remove).

See Cleaning Glass on Page 11.

Gas Pressure

Tables 2 and 3 show the appliances' gas

pressure requirements.

Inlet Gas Supply Pressure

(all models)

Fuel #

Minimum

Maximum

Natural Gas

4.5" WC

(1.12 kPa)

10.5" WC

(2.61 kPa)

Propane

11.0" WC

(2.74 kPa)

13.0" WC

(3.23 kPa)

Table 2

Manifold Gas Supply Pressure

(all models)

Fuel #

Low

High

Natural

Gas

(Lo) 1.6" WC

(0.40 kPa)

(Hi) 3.5" WC

(0.87 kPa)

Propane (Lo) 6.3" WC

(1.57 kPa)

(Hi) 10.0" WC

(2.49 kPa)

Table 3

Test gauge connections are provided on the

front of the gas control valve, identified IN for

the inlet and OUT for the manifold side (see

Figure 1). A 1/8" NPT Test gauge connection

is provided at the inlet and outlet (manifold)

ports.

BTU Input

Electronic models come standard with a re-

mote controlled modulating gas valve; flame

appearance and heat output can be varied.

The BTU Input for these appliances are shown

in Table 1.

These appliances must be isolated
from the gas supply piping system (by
closing their individual manual shut-off
valve) during any pressure testing of
the gas supply piping system at test
pressures equal to or less than 1/2 psig
(3.5 kPa).

These appliances and their individual
shut-off valves must be disconnected
from the gas supply piping system dur-
ing any pressure testing of that system
at pressures greater than 1/2 psig (3.5
kPa).

Burner Orifice Sizes

Elevation 0-4500 feet ( 0-1372 meters)

Model

Series

Nat.Gas

drill size (inches)

Propane

drill size (inches)

SYM-35

#35 (0.110")*

21L80•

(0.062")*

21L01•

SYM-40

#32 (0.116")*

37L82•

(0.065")*

74L88•

SYM-45

(0.119")*

39L09•

(0.068")*

H7875•

Table 4

* Standard size installed at factory

• Part /Cat. Number

Input (BTU/HR) (all models)

Models

Input Rate (BTU / HR)

Natural Gas

Propane Gas

SYM-35

33,000 high

21,500 low

27,500 high

21,000 low

SYM-40

37,000 high

23,500 low

32,000 high

24,500 low

SYM-45

39,000 high

26,000 low

33,500 high

26,000 low

Table 1

Figure

1

SIT

Proflame

Valve

Orange Wire

(From DFC Wire

Harness)

Pressure

Regulator

Tower

Yellow Ground Wire

(From DFC Wire

Harness)

Green Wire

(From DFC Wire

Harness)

Line (In) Test Port

Manifold (Out)

Test Port

Connect GTMS

Wire Harness