4.

Remove

the

hard

disk

drive

fan

assembly:

a.

Disconnect

the

hard

disk

drive

fan

assembly

cable

from

the

system

board

and

make

a

note

of

where

the

cable

was

connected

for

later

installation.

b.

Remove

all

hard

disk

drives.

c.

Press

and

hold

the

drive

cage

release

tab

on

the

side

of

the

drive

cage;

then,

rotate

the

drive

cage

out

of

the

chassis

until

the

retaining

tab

on

top

of

the

cage

locks

into

place.

d.

Pull

out

on

the

hard

disk

drive

fan

assembly

release

tabs

(at

the

blue

dots);

then,

rotate

the

hard

disk

drive

fan

assembly

away

from

the

drive

cage

slightly.

5.

Disconnect

the

signal

and

power

cables

and

the

existing

SAS/SATA

controller

(if

one

is

installed);

then,

remove

the

controller

from

the

server.

6.

Touch

the

static-protective

package

that

contains

the

ServeRAID-MR10i

SAS/SATA

controller

to

any

unpainted

metal

surface

on

the

server.

Then,

remove

the

ServeRAID-MR10i

SAS/SATA

controller

from

the

package.

7.

Align

the

ServeRAID-MR10i

SAS/SATA

controller

so

that

the

keys

align

correctly

with

the

connector

on

the

system

board.

Attention:

Incomplete

insertion

might

cause

damage

to

the

system

board

or

the

ServeRAID-MR10i

controller.

1

Hard

disk

drive

cable

connector

4

-

7

4

ServeRAID-MR10i

SAS/SATA

controller

2

Hard

disk

drive

cable

connector

0

-

3

5

Hard

disk

drive

cable

4

-

7

3

Battery

6

Hard

disk

drive

cable

0

-

3

44

ThinkServer

TS100

Types

6431,

6432,

6433,

and

6434:

User

Guide

Advertising
This manual is related to the following products: