Installing an optional mini-pci-x enablement card, Installing, Optional – Lenovo 6434 User Manual

Page 59: Mini-pci-x, Enablement, Card

Advertising
background image

Note:

The

drive

cage

should

be

in

the

open

position.

This

illustration

shows

it

in

the

closed

position.

8.

Press

the

ServeRAID-MR10i

SAS/SATA

controller

firmly

into

the

connector

on

the

system

board.

9.

Take

the

other

end

of

the

signal

cable

that

is

attached

to

the

drive

backplane

section

for

drive

bays

0

through

3

(as

labeled

on

the

front

of

the

drive

cage)

and

connect

it

to

the

connector

that

is

closest

to

the

battery

on

the

ServeRAID-MR10i

SAS/SATA

controller.

If

drives

are

installed

in

drive

bays

4

through

7

(as

labeled

on

the

front

of

the

drive

cage),

take

the

other

end

of

the

signal

cable

that

is

attached

to

drive

backplane

section

for

drive

bays

4

through

7

and

connect

it

to

the

connector

that

is

farthest

from

the

battery

on

the

ServeRAID-MR10i

SAS/SATA

controller.

10.

Replace

the

hard

disk

drive

fan

assembly:

a.

Insert

the

hard

disk

drive

fan

assembly

retaining

tab

over

the

right

edge

of

the

hard

disk

drive

backplane;

then,

rotate

the

hard

disk

drive

fan

assembly

toward

the

backplane.

Do

not

fully

close

the

hard

disk

drive

fan

assembly.

b.

Route

the

signal

cables

and

power

cable

through

the

slot

on

the

edge

of

the

hard

disk

drive

fan

assembly.

Make

sure

that

the

cables

will

not

be

pinched

between

the

hard

disk

drive

fan

assembly

and

the

hard

disk

drive

backplane

when

the

assembly

is

installed.

c.

Rotate

the

hard

disk

drive

fan

assembly

toward

the

backplane

until

the

release

tabs

are

fully

engaged

and

snap

into

place.

11.

Reconnect

the

hard

disk

drive

fan

assembly

cable

to

the

system

board.

12.

Rotate

the

drive

cage

back

into

the

server

until

it

stops;

then,

press

and

hold

the

retaining

tab

on

top

of

the

drive

cage

while

you

rotate

the

drive

cage

into

the

chassis

until

it

is

in

the

closed

position.

13.

Reinstall

the

hard

disk

drives.

Note:

Before

you

continue,

check

all

internal

power

cables

to

make

sure

that

they

are

connected

to

the

system

board

and

other

optional

devices.

14.

Install

the

side

cover

(see

“Reinstalling

the

side

cover”

on

page

52).

15.

Lock

the

side

cover.

16.

Reconnect

the

external

cables

and

power

cords;

then,

turn

on

the

attached

devices

and

turn

on

the

server.

Installing

an

optional

mini-PCI-X

enablement

card

To

install

an

optional

mini-PCI-X

enablement

card,

complete

the

following

steps:

1.

Read

the

safety

information

that

begins

on

page

v

and

“Installation

guidelines”

on

page

19.

2.

Turn

off

the

server

and

all

attached

devices;

then,

disconnect

all

power

cords

and

external

cables.

3.

Unlock

and

remove

the

side

cover

(see

“Removing

the

side

cover”

on

page

23).

4.

Touch

the

static-protective

package

that

contains

the

mini-PCI-X

enablement

card

to

any

unpainted

surface

on

the

outside

of

the

server;

then,

remove

mini-PCI-X

enablement

card

from

the

package.

Chapter

2.

Installing

optional

devices

45

Advertising
This manual is related to the following products: