Natural gas, Propane/lpg – Lennox Hearth INTERTEK LMBV-42REN User Manual

Page 19

Advertising
background image

19

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

LENNOX HEARTH PRODUCTS • MERIT

®

SERIES B-VENT GAS FIREPLACES • 42" LMBV MODELS • INSTALLATION INSTRUCTIONS

THIS APPLIANCE HAS BEEN CONVERTED TO:

NATURAL GAS

INPUT BTU/HR – 30,000
MANIFOLD PRESSURE – 3.5"
ORIFICE SIZE – #37 (0.104)

THIS APPLIANCE HAS BEEN CONVERTED TO:

PROPANE/LPG

INPUT BTU/HR – 30,000
MANIFOLD PRESSURE – 10"
ORIFICE SIZE – (0.065)

Step 5. All Millivolt Systems – Attach ma-

nometer to the manifold side pressure test

fitting and verify manifold pressure reads

3.5" water column (0.87 kPa) for natural

gas, and 10.0" water column (2.49 kPa)

for propane gas.

Step 6. Refer to Figure 30 and remove the

pilot hood assembly to access the hexed pilot

orifice. Remove and replace the orifice with

the one provided with the kit.

electronic Appliances

Step 7. Honeywell electronic valves - See

Figure 32 and the instructions provided

with the kit. Remove the slotted cap screw,

o-ring, pressure-regulating adjusting screw

and spring. Retain all parts for possible later

use. Install new components from the kit.

Black cap and red spring for propane gas

units. Silver cap and stainless steel spring

fro natural gas units.

Before installing the cap, attach manometer

to the manifold side pressure test fitting and

adjust screw until pressure reads 3.5" water

column (0.87 kPa) for natural gas, and 10.0"

water column (2.49 kPa) for propane gas.

Figure 31

pilot

Orifice

pilot

Assembly

Igniter

Assembly

Retaining

Clip

Flare Nut

NOTE: If the igniter is damaged, a replacement

kit is available, order Catalog No. 87L54.

Figure 32

Figure 33

When reinstalling the igniter assembly,

use extreme care to prevent damage and

breakage. Do not apply any leverage to

the igniter assembly while restoring the

retainer clip to its original position.

All models

Step 8. Unscrew the orifice from the manifold

and replace it with the one provided with the kit,

#37 (0.104) for natural gas units and (0.065)

for propane (see Figure 33).

See Figure 31 and replace the pilot orifice as

follows: Remove the Igniter assembly retainer

clip, and carefully remove the igniter assembly.

exercise extreme care to prevent damage to

or breakage of the igniter assembly. Remove

the screw securing the pilot assembly to its

mounting bracket. Back off the flare nut at

the end of the pilot gas line to free the pilot

assembly from the gas line. Remove the pilot

orifice and replace it with the one provided with

the conversion kit. Reinstall the pilot assembly

by reversing the steps detailed here.

Spring

Adjusting

Screw

Slotted

Cap

P

S

I

OF
F

I

ON

CONTROL

IG

N

IT

E

Manifold

Pressure

Test Port

Inlet Pressure Test Port

burner Orifice Sizes (all models)

elevation

Feet (meters)

Natural

Gas

drill size (inches)

propane

Gas

drill size (inches)

0-4500

(0-1372)

#37 (0.104")

*

H5830 •

1.65mm (0.065")

*

H5831 •

Table 5

* Standard size installed at factory

• Part /Cat. Number

Step 11. Turn on gas supply and test for gas

leaks.

Step 12. Attach manometer to the manifold

side pressure test fitting and verify manifold

pressure reads 3.5" water column (0.87 kPa)

for natural gas, and 10.0" water column (2.49

kPa) for propane gas.

Step 9. Reassemble all removed components

by reversing the procedures outlined in the

preceding steps. Use pipe joint compound or

Teflon tape on all pipe fittings before installing

(ensure propane resistant compounds are used

in propane applications, do not use pipe joint

compounds on flare fittings). Check for leaks

(refer to Page 11, Step 6).

Step 10. Attach appropriate conversion kit

label (see Figure 34) next to the rating plate

on the appliance.

Figure 34