NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

CAUTION

THIS AppLIANCe CANNOT be veNTeD HORIZONTALLY.

LENNOX HEARTH PRODUCTS • MERIT

®

SERIES B-VENT GAS FIREPLACES • 42" LMBV MODELS • INSTALLATION INSTRUCTIONS

12 ft.

Minimum

60*

degrees

Maximum

Back View

Of Appliance

12 ft.

Minimum

Back View

Of Appliance

*12 ft. Min.

**15 ft. Min.

2 ft.

Minimum

To Offset

*with an offset up to 45 degrees

** with an offset greater than 45

degrees and up to 60 degrees

Back View

Of Appliance

*This Vent Configuration

Allowable only With The

Following optional Non-

Operable Glass Doors Installed:

42GEP or 42GEP-BB

Figure 11

1

2

3

Figure 10

Step 3. position Appliance

Slide the fireplace into prepared framing or posi-

tion fireplace in its final position and frame later.

Refer to fireplace drawings and specifications

on Page 7 for framing dimensions and details.

Framing header may be positioned directly on

the fireplace top spacers.

ImpORTANT: UNDeR NO CIRCUmSTANCeS

CAN THe FIRepLACe TOp SpACeRS (REFER

TO FIGuRE 8) be RemOveD OR mODIFIeD,

NOR mAY YOU NOTCH THe HeADeR TO FIT

AROUND OR be INSTALLeD LOWeR THAN THe

SpACeRS. THe HeADeR mAY be IN DIReCT

CONTACT WITH THe TOp SpACeRS bUT mAY

NOT be SUppORTeD bY THem.

Fireplace should be secured to side framing

members using the full length 1/2" nailing

flanges that are integral to the appliance at each

side. Use 8d nails or equivalent.

NOTE: The nailing tabs and the area directly

behind the nailing tabs are exempt from the clear-

ances described on the fireplace clearance label.

6”

Type B-Vent

Flue Outlet

Collar

Securing

Screws

Step 4. Install vent System and

exterior Termination

A. Connect a 6" (152 mm) Type B vent system

to the appliance flue collar with four (4)

No. 8 sheet metal screws (Figure 10) and

install the remainder of the Type B vent to

the outside.

b. The following venting configurations may

be installed (see Figure 11):

- vertical - Minimum overall height of

the vent system and appliance without an

offset must be 12' (3.66 m)

- With Offset

a.

Minimum overall height of the vent

system and appliance must be 12' (3.66

m) when an offset up to 45 degrees

from the vertical is used. There must

be a minimum vertical vent height of

2 ft (0.6 m) above the appliance collar

before the offset can be applied.

b.

Minimum overall height of the vent

system and appliance must be 15'

(4.57 m) when an offset, more than

45 degrees but less than 60 degrees

from the vertical, is used. There must

be a minimum vertical vent height of

2 ft (0.6 m) above the appliance collar

before the offset can be applied.

- With Offset, when using the optional,

42Gep or 42Gep-bb, non-operable glass

doors

Minimum overall height of the vent system

and appliance must be 12' (3.66 m) when

an offset up to 60 degrees from the vertical

is used. The lower part of the offset may

start at the appliance flue collar.

Maximum overall height of the vent system and

appliance should not exceed 40 feet (12.19 m).

Install the B-vent system in accordance with the

vent manufacturer's instructions.

CAUTION: THIS AppLIANCe CANNOT be

veNTeD HORIZONTALLY.

NOTE: Refer to the vent manufacturers instal-

lation instructions for variations of venting

techniques. If common venting of several units

is contemplated, it should be discussed with an

architect and the local Building Department.

Install the B-vent system in accordance with

the vent manufacturer's instructions.