Impinger, Utility specifications required – gas – Lincoln IMPINGER 1200 User Manual

Page 4

Advertising
background image

Impinger I – 1000 Series Ops Manual

4

IMPINGER

®

I AND III CONVEYOR OVENS – MODEL SERIES 1000 AND 1200

UTILITY SPECIFICATIONS REQUIRED – ELECTRIC

Model

Energy

Power

Voltage

Current

Phase

Hz

Recommended Electrical

Specifications

Agency

Listing

***1021-xxx-E

Electric

27 kW

400/230 VAC

40 Amps

3

50 Hz

5 Wires, 3 Poles

1N-1G

F-G

1022

Electric

27 kW

120/208 VAC

80 Amps

3

60 Hz

5 Wires, 3 Poles

1N-1G

A-B-F

1023

Electric

27 kW

120/240 VAC

70 Amps

3

60 Hz

5 Wires, 3 Poles

1N-1G

A-B-F

1028

Electric

27 kW

380Y/220

VAC

41 Amps

3

50 Hz

5 Wires, 3 Poles

1N-1G

F

1029

Electric

27 kW

415/240 VAC

38 Amps

3

50 Hz

5 Wires, 3 Poles

1N-1G

F

1032

Electric

27 kW

380Y/220

VAC

41 Amps

3

50 Hz

5 Wires, 3 Poles

1N-1G

F

1202

Electric

27 kW

120/208 VAC

80 Amps

3

60 Hz

5 Wires, 3 Poles

1N-1G

A-B-F

1203

Electric

27 kW

120/240 VAC

70 Amps

3

60 Hz

5 Wires, 3 Poles

1N-1G

A-B-F

1228

Electric

27 kW

380Y/220

VAC

41 Amps

3

50 Hz

5 Wires, 3 Poles

1N-1G

F

1229

Electric

27 kW

415/240 VAC

38 Amps

3

50 Hz

5 Wires, 3 Poles

1N-1G

F

UTILITY SPECIFICATIONS REQUIRED – GAS

Model

Energy

Power

Voltage

Current

Phase

Frequency

Recommended

Electrical

Specification

Gas

Agency

Listing

1030

Nat. Gas

35 kW

220

VAC

1.6 Amps

1

50 Hz

3 Wires, 1 Pole

1N-1G

35 kW/hr at 17.5

mB H

2

O column

F

1031

L.P. Gas

35 kW

220

VAC

1.6 Amps

1

50 Hz

3 Wires, 1 Pole

1N–1G

35 kW/hr at 27.5

mB H

2

O column

F

***1033-xxx-E

Nat. Gas

35 kW

230

VAC

3 Amps

1

50 Hz

3 Wires, 1 Pole

1N-1G

35 kW/hr at 17.5

mB H

2

O column

F-G

***1034-xxx-E

L.P. Gas

35 kW

230

VAC

3 Amps

1

50 Hz

3 Wires, 1 Pole

1N-1G

35 kW/hr at 27.5

mB H

2

O column

F-G

1040

Nat. Gas

120,000

BTU

120/230

VAC

5 Amps

1

60 Hz

4 Wires, 1 Pole

1N-1G

120,000 BTU at 7

inches H

2

O column

A-F

1041

L.P. Gas

120,000

BTU

120/230

VAC

5 Amps

1

60 Hz

4 Wires, 1 Pole

1N-1G

120,000 BTU at 11

inches H

2

O column

A-F

1042

Nat. Gas

120,000

BTU

230

VAC

5 Amps

1

50 Hz

3 Wires, 1 Pole

1N-1G

120,000 BTU at 7

inches H

2

O column

F

1043

L.P. Gas

120,000

BTU

230

VAC

5 Amps

1

50 Hz

3 Wires, 1 Pole

1N-1G

120,000 BTU at 11

inches H

2

O column

F

1046

Nat. Gas

126 MJ

240

VAC

5 Amps

1

50 Hz

3 Wires, 1 Pole

1N-1G

126 MJ/hr at 1.75

kPa H

2

O column

E-F

1047

L.P. Gas

126 MJ

240

VAC

5 Amps

1

50 Hz

3 Wires, 1 Pole

1N-1G

126 MJ/hr at 1.75

kPa H

2

O column

E-F

1240

Nat. Gas

120,000

BTU

120/230

VAC

5 Amps

1

60 Hz

4 Wires, 1 Pole

1N-1G

120,000 BTU at 7

inches H

2

O column

A-F

1241

L.P. Gas

120,000

BTU

120/230

VAC

5 Amps

1

60 Hz

4 Wires, 1 Pole

1N-1G

120,000 BTU at 11

inches H

2

O column

A-F

1242

Nat. Gas

120,000

BTU

230

VAC

5 Amps

1

50 Hz

3 Wires, 1 Pole

1N-1G

120,000 BTU at 7

inches H

2

O column

F

1243

L.P. Gas

120,000

BTU

230

VAC

5 Amps

1

50 Hz

3 Wires, 1 Pole

1N-1G

120,000 BTU at 11

inches H

2

O column

F

NOTE: All ovens require separate service and dedicated neutral.