Impinger I – 1000 Series Ops Manual

5

****NOTE: For proper operation, the gas valve

requires a nominal inlet pressure of 7 inches H

2

O

column for natural gas and 11 inches of H

2

O column

for L.P. gas. A minimum inlet pressure of 1.0 inch of
H

2

O above the manifold setting (NAT. manifold 3.5”

H

2

O, L.P. manifold 10” H

2

O) must be maintained with

no pressure drop from the no load to full load

condition. The maximum inlet pressure must be

maintained at or below ½ PSIG (14.5 inches H

2

O

column). Refer to the chart on the left for pressure

conversions.

IMPINGER

®

CONVEYOR OVENS – MODEL SERIES 1400

UTILITY SPECIFICATIONS REQUIRED – ELECTRIC

Model

Energy

Power

Voltage

Current

Phase

Hz

Recommended Electrical

Specifications

Agency

Listing

***1421-xxx-E

Electric

27 kW

400/230 VAC

40 Amps

3

50 Hz

5 Wires, 3 Poles

1N-1G

F-G

1452

Electric

27 kW

120/208 VAC

80 Amps

3

60 Hz

5 Wires, 3 Poles

1N-1G

A-B-D-F

1453

Electric

27 kW

120/240 VAC

70 Amps

3

60 Hz

5 Wires, 3 Poles

1N-1G

A-B-D-F

1454

Electric

27 kW

380/220 VAC

41 Amps

3

50 Hz

5 Wires, 3 Poles

1N-1G

F

1455

Electric

27 kW

415/240 VAC

38 Amps

3

50 Hz

5 Wires, 3 Poles

1N-1G

F

UTILITY SPECIFICATIONS REQUIRED – GAS

Model

Energy

Power

Voltage

Current

Phase

Frequency

Recommended

Electrical

Specification

Gas

Agency

Listing

***1433-xxx-E

Nat. Gas

35 kW

230 VAC

3 Amps

1

50 Hz

3 Wires, 1 Pole

1N-1G

35 kW/hr at 17.4

mB H

2

O column****

F-G

***1434-xxx-E

L.P. Gas

35 kW

230 VAC

3 Amps

1

50 Hz

3 Wires, 1 Pole

1N–1G

35 kW/hr at 27.4

mB H

2

O column****

F-G

1450

Nat. Gas

120,000

BTU

120 VAC

5 Amps

1

60 Hz

3 Wires, 1 Pole

1N-1G

120,000 BTU at 7

inches H2O column****

A-D-F

1451

L.P. Gas

120,000

BTU

120 VAC

5 Amps

1

60 Hz

3 Wires, 1 Pole

1N-1G

120,000 BTU at 11

inches H2O column****

A-F

1456

Nat. Gas

120,000

BTU

220/240

VAC

5 Amps

1

50 Hz

3 Wires, 1 Pole

1N-1G

120,000 BTU at 7

inches H2O column****

E-F

1457

L.P. Gas

120,000

BTU

220/240

VAC

5 Amps

1

50 Hz

3 Wires, 1 Pole

1N-1G

120,000 BTU at 11

inches H2O column****

E-F

A

B

C

D

E

F

G

H

Agency

Listing

CSA

UL

MEA

AGA*

NSF

CE

Electrical Supply for Australia:

Single Phase: 240VAC, 50Hz / 20 Amp: one neutral & one earth/ground.

Three Phase: 240/415 VAC / 20 Amp; three active, one neutral & one earth/ground.

* AGA Australian Gas Association

** In Australia, use a 10 Amp General Purpose Outlet

*** Reference Model Key

All ovens require separate service and dedicated neutral.

GAS PRESSURE CONVERSION CHART

Inches of

Water Column

KPa

m-Bar

Millimeters of

Water Column

3.5

4.5

7

10

10.5

11

14

14.5

0.87

1.12

1.74

2.48

2.61

2.73

3.48

3.61

8.70

11.2

17.40

24.87

26.11

27.36

34.81

36.05

88.9

114.3

177.8

254.0

266.7

279.4

355.6

368.3