Lennox Hearth Ladera-BN User Manual

Page 11

Advertising
background image

Once the repair is done, it is mandatory to

apply a new high temperature black cement

-ILL 0ACK AVAILABLE FROM YOUR RETAILER

sealing the access plate and all screw holes.

Because the Ladera™ fireplace is an air tight

fireplace, failure to do so will reduce fireplace

efficiency. Tightly screw the access plate back

on place and reinstall the bottom refractory.

HOT AIR DUCTING INSTALLATION

The Ladera fireplace is approved for use with a

Gravity kit (hot air ducting system).

Gravity Kit

The gravity kit is designed for double hot air

outlets and includes: (See Figure 14).

- Two (2) telescopic lengths 8” I.D.

- Two (2) 90º elbows 8” I.D.

- Two (2) hot air outlet kits

(grill and frames)

- Two (2) adaptors

See Gravity Kit Accessories Page 21.
For safe installation, the gravity kit must meet

the following requirements:

Minimum height* 68” (1,727 mm)

Maximum length See Figure 15

* The height of the louver must be measured

from the base of the Ladera fireplace to the

middle point of the louver.
The only blower that can be used with the gravity

kit is the one sold with the fireplace.
To extend the double outlet system, it will be

necessary to purchase two adjustable lengths

(H8951).

Figure 14

Figure 15

Frame

Grill

Only non-combustible mate-

rial should be superposed or

projecting over the front of

the fireplace.

Noncombustible Facing

Drywall

2” X 3” Min.

Rock Board or Other

Spacer

Figure 12

13” x 13”



M

Max.

Figure 13

Maintain at least 6-1/2”

(160 mm) clearance from

the outlet grill framing to

a combustible ceiling,

side wall or mantel.

Outlet Grill

Outlet Grill

WARNING: The outlet grills

should not be installed fac-

ing upward through a floor.

Danger of burns can result

if grills in floor are stepped

on.

38”

MM

Min.

MM X MM

 M

Max.

FIREPLACE BLOWER

The fireplace is equipped with a blower. It is

located in the bottom of the fireplace towards

the back. It uses 120V and must be connected to

the main electrical circuit by a qualified electri-

cian prior to enclosing the fireplace.
For connection, use the electrical box supplied

with the unit located on the bottom right side

of the fireplace. To access the electrical box

remove the four screws, pull out the plate and

box and install the electrical receptacle.
! WALL ONOFF SWITCH MUST BE INSTALLED TO CONTROL

the blower. An optional heat switch and variable

speed control are available (see Page 22).
If installed, the heat activated switch must be

connected to the blower main cable and the

magnets must be stuck under the fireplaces

firebox accessible through the side electrical

box access plate.
If a repair must be done after the fireplace is

installed an access plate is located under the bot-

tom refractory. Remove the bottom refractory,

unscrew the access plate, clean black cement

sealing the access plate and do the repair.

WARNING: Both pipes of

the double hot air outlet

must be installed. Any oth-

er installation may cause

fire and void warranty.

./4% $)!'2!-3  ),,5342!4)/.3 !2% ./4 4/ 3#!,%

11

When installing the double outlet system, the

hot air outlets can be installed in the same room

as the fireplace, or one or both of the outlets

can be installed in adjacent or upper rooms.

Installing the ducts at different elevations will

tend to exhaust more heat out of the higher

outlet (Figure 15).