#()-.%9 ).34!,,!4)/.

INSTRUCTIONS

1. Cut and frame the holes in the ceiling, floor

and roof where the chimney will pass (see

Figure 23). 5SE A PLUMB BOB TO LINE UP THE

center of the holes. The sizes are indicated

in Table 2 for the floor and ceiling holes and

Table 3 (Page 16) for the roof holes.

 &ROM BELOW INSTALL A lRESTOP IN EACH CEILING

floor separation through which the chimney

will pass. At the attic level, install an attic

radiation shield from above (Figure 24a).

 &OR!3(4 (4 AND3 (4

chimneys place the first chimney length on

THE lREPLACE 4O LOCK IT IN PLACE TURN  OF

a turn clockwise. With the AC chimney, you

must use a starter section before installing

the first chimney length (Figure 25). Con-

tinue installing chimney lengths making sure

to lock each length in place.

4. Every time the chimney passes through

a ceiling or a wall, install the appropriate

firestop. When you reach the desired height,

install the roof support. When installing a

support, slightly lift the chimney system so

the weight will lie on the support, not on the

fireplace to reduce expansion noises (Refer

to instructions included with the support).

5. Then, put the roof flashing in place and seal

the joint between the roof and the flashing

with roofing pitch (see Figures 26 and 27).

For sloping roofs, place the flashing under

the upper shingles and on top of the lower

shingles. Nail the flashing to the roof, using

roofing nails.

6. Place the spacers and the storm collar over

the flashing, and tighten it with the bolt

supplied. Finally, seal the joint between the

storm collar and the chimney, using silicone

caulking.

7. Install the chimney cap. Once the chimney

cap is in place, the roof flashing can be

washed with a solvent or vinegar and then

painted with rust-proof paint.

#()-.%9 -/$%, *

6”

SQUARE HOLE

3):% /0%.).'

ASHT+ / HT6103+

 v  MM

S-2100+ / HT6000+

 v  MM

AC

 IN  MM

NOTE: See Table 3 for Sloped Roof Framing

Table 2 - Flat Roof Framing

Figure 25

Rain Cap

Collar

Flashing

Attic Radiation

Shield

Firestop

Universal Support

Optional Outside

Combustion Air Kit

AC Starter Section

Figure 23 - Roof Framing

!# #()-.%9

*

INSTALLATION

!)2 #//,%$ '!,6!.):%$ #()-.%9

Figure 24a

Attic Radiation Shield

ASHT / S2100

HT6103+ / HT6000+

Solid Packed Pipe *

AC

Air Cooled Pipe *

Figure 24b

Radiation Shield

Attic Radiation

Shield

Firestop

X

Combustibles are not allowed below

top spacers above the fireplace. Facing in

front of fireplace must be non-combustible

below this area.

X

Chimney Outside

Air Intake

REQUIRED WHEN

USING !# CHIMNEY

*

Available from Security Chimneys™

15

./4% $)!'2!-3  ),,5342!4)/.3 !2% ./4 4/ 3#!,%