If possible, you should choose a location where

the chimney will pass through the house without

cutting floor or roof joists (see fireplace dimen-

sions Page 9).

5SUALLY NO ADDITIONAL mOOR SUPPORT IS NEEDED

for the fireplace. The adequacy of the floor

can be checked by first estimating the weight

of the fireplace system. Weights are given

on Page 22. Note the floor construction and

consult your local building code to determine

if additional support is needed.

The Ladera fireplace may be installed directly

on the floor or on a raised base (for proper

guidelines, refer to “Hearth Extension Require-

ments”) and a minimum of 6’8” (2 m) measured

from the base of the appliance to the ceiling

is required.

When selecting the location, the chimney outlet

position and the direction of the wind are impor-

tant factor affecting the chimney performance.

To allow a maximum draft and to reduce wind

turbulence, the chimney must:

s 0ENETRATE THE HIGHEST PART OF THE ROOF

s "E INSTALLED AS FAR AS POSSIBLE OF ROOF OFFSETS

trees or any other obstructions that may

cause wind turbulence and back drafts in

the chimney.

s 4HE LEAST AMOUNT OF OFFSETS ELBOWS POS-

sible. NOTE: A maximum of 2 offsets is

allowed.

GLASS CARE

Glass Replacement

The glass used for the Ladera™ fireplace is a high

TEMPERATURE CERAMIC GLASS  — &  — # 

If the glass breaks, it must be replaced with

an identical ceramic glass. Tempered glass

or ordinary glass will not withstand the high

temperatures of the Ladera fireplace. Replace-

ment glass should be purchased from a IHP

dealer (see “Replacement Parts”, Page 22).

DO NOT OPERATE THE UNIT WITH CRACKED

OR BROKEN GLASS.

Glass Cleaning

The Ladera fireplace is designed to keep the

glass clean under normal operating conditions.

If the Ladera fireplace is operated continuously

with the combustion air controls closed, the

glass will tend to get dirty unless the fuel, firebox

and glass are maintained at hot temperatures

(see “Refueling For Best Performance”). To

clean the glass, there are a number of specially

designed cleaners. Your IHP dealer can recom-

mend a suitable cleaner which is available in

your area. Regular household glass cleaners

will not clean creosote. Do not use abrasives

such as steel pads, steel wool or oven cleaner

as they will scratch the glass.

DO NOT USE CHEMICAL GLASS CLEANERS

/. 0!).4%$ 352&!#%3 !3 )4 -!9 #!53%

THE PAINT TO PEEL.

CAUTION : DO NOT ALLOW WINDOW CLEANER

TO GET IN CONTACT WITH DOOR GASKET OR

PAINT ON FACADE OR DOOR. ONCE CLOSED,

CONTACT OF GLASS CLEANER WITH THE

FIREPLACE FACADE CAN PROVOKE PAINT

PEELING OFF.

FIREPLACE INSTALLATION

Locating The Ladera Fireplace

The best location to install your fireplace is

determined by considering the location of

windows, doors, and the traffic flow in the room

where the fireplace is located, allowing space

in front of the unit for the hearth extension and

the mantel, and taking into consideration the

location of the hot air ducts (optional), outside

air kit (optional) and chimney.

Gasket Replacement

Remove the door from the unit (see Page 6)

and lay it on a clean unabrasive surface. To

replace the gasket, first remove all of the old

gasket and gasket cement. Make sure that the

surface is totally clean before applying new

cement (a high temperature silicone caulking

rated at 500° F [260° C], is suitable) or adhesion

problems may result. Apply gasket cement to

the gasket channel and install the new gasket.

This replacement part is available from your IHP

dealer in the following dimensions:

Marginal Location

Wind Direction

Location

Not

Recommended

Outside Air Intake

Facing the Wind

Location

Not

Recommended

Location Recommended

Figure 6

./4% $)!'2!-3  ),,5342!4)/.3 !2% ./4 4/ 3#!,%

Gasket

Length* Dimensions

Part No.

Around

Glass

69

(1753)

 X 

(25 x 4.8)

PR-SR1685H

On Door

Frame

73

(1854)

 DIA

(19.5)

PR-SR1823O

Table 1

*NOTE: Inches (millimeters)

7