Caution – Lennox Hearth Winslow (PS40) User Manual

Page 5

Advertising
background image

5

FEATURES AND SPECIFICATIONS

CAUTION

THE USE OF UNAPPROVED, DIRTY, WET AND/OR

HIGH SALT CONTENT FUEL WILL VOID THE WAR-

RANTY!

Installation Options

• Residential

• Vented vertical and horizontal (see venting instructions)

• Manufactured home and mobile home

• Thermostat or manual operation

• Bedrooms

Heating

• Max. feed rate is 4.7 pounds/hour or 39,500 BTU/hour

• Min. feed rate is 1.8 pounds/hour or 15,120 BTU/hour

Venting

This stove is approved for venting with Type L and Type PL pellet vent
pipe listed to UL 641 and ULC S609. We recommend the use of venting
products manufactured by Security Chimneys International.. The flue

collar on the stove accepts 3” diameter pipe.

The combustion air for this stove is drawn through a pipe at the lower

rear of the stove. For mobile home installations a 3” ID flex line or pipe

must be attached to the stove’s air intake to draw air from outside the

house. The vent pipe can be installed vertically or horizontally (see Venting

section for recommended installations).

Note: When installing this stove at altitudes of 4000 feet and above, we

suggest the use of 4” pellet vent.

Thermostat

This stove can be operated manually or with a thermostat.

Lighting

This stove is equipped with an electric self igniter for ease of ignition.

Fuel Specifications

This stove is designed to burn wood pellet fuel. In addition, a corn/wood

pellet mixture, with a maximum of 50 percent corn can be burned. Burning

any other fuel that is not approved for use with this appliance will void the

appliance warranty. IMPORTANT: The corn/wood mix needs to be mixed

evenly before being put in the Winslow™ pellet stove hopper.

Wood Pellet Specifications: This appliance has been designed to burn

wood residue pellets with up to 3% ash content. Dirty fuel will adversely

affect the performance of the stove. Any questions regarding pellet fuel

Wood pellets manufactured to the pellet fuels institute (P.F.I.) certification

standard are available in two grades, Standard and Premium. The primary

difference between the two is the ash content of the pellets.

The P.F.I. specification for standard grade and premium grade residential

pellet fuel is as follows:

• CHLORIDES (Salt): Less than 300 p.p.m. to avoid stove and vent

rusting.

• BULK DENSITY: 40 lb. / Cu. Ft. minimum

• MOISTURE CONTENT: 8% maximum

• ASH CONTENT: < 3% maximum (standard grade) < 1% maximum

(premium grade)

• FINES: 0.5% maximum through a 1/8” screen

• BTU CONTENT: There are a number of variations in pellet fuels that are

not included in PFI standards. For example, BTU (heat value) content

may range from just under 8,000 to almost 9,000 Btu, depending upon

species and region of the country and other variables.

Corn Specifications: Use only clean-shelled corn with a moisture content

less than 15% and approximate fuel value of 7000 BTU/lb (16,200 kJ/kg).

Do not attempt to burn corn with higher moisture content or burn lesser

grade fuels. Do not burn other types of agricultural pellets or by-products

(alfalfa, cherry pits, olive pits, nut shells, etc.) as they are not permitted

to be burned in these appliances.

Weight - 305 pounds

Hopper Capacity - 60 pounds

Listing information

The Winslow™ PS40 stove is safety tested and listed with the following

agencies;

• OMNI-Test Laboratories, Inc., Portland, Oregon to ASTM E 1509

• US EPA List of Approved Wood Heating Appliances

• List of Colorado Approved Pellet Stoves

Appearance Choices

The Winslow PS40 stove can be ordered with the following door trims

and grills, log set and brick panel options:

Door Trim Kits

Grill Kits

Black .......................79038

Black ............................ 79000

Gold .......................79034

Gold ............................. 79001

Nickel .....................79037

Nickel .......................... 79002

Brushed Nickel ........79035

Brushed Nickel ............ 79022

Black Nickel ............79036

Black Nickel ................. 79039

Log Set .............................. H5142

Brick Panel Kit ..................... 79030