NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

carbon Monoxide poisoning: early signs of

carbon monoxide poisoning are similar to the

flu with headaches, dizziness and/or nausea. if

you have these signs, obtain fresh air immedi-

ately. turn off the gas supply to the appliance

and have it serviced by a qualified professional,

as it may not be operating correctly.

operation and care oF Your

appLiance

Appliance operation may be controlled by the

following means: the factory provided unit-

mounted ON-OFF control switch, a remotely

located optional wall switch or optional remote

control. See Figure 1.

Burn-in period

During the first few fires of this appliance there

will be some odor due to the curing of the

paint and burning off of lubricants used in the

manufacturing process.

Depending on your use, the burn-in period may

take a few hours or a few days.

Keep Your House WeLL VentiLated

durinG tHe curinG process. tHe odor

and Haze eMitted durinG tHe curinG

process can Be Quite noticeaBLe and

MaY set oFF a sMoKe detector.

If an optional blower is installed, Do not turn it

on during the Burn-In period.

A white film may develop on the glass front

during the first few fires as part of the curing

process. The glass should be kept clean during

the first two weeks of use to prevent the film from

baking on (making it very difficult to remove).

See Glass Cleaning on Page 4.

Table 1 shows the units' gas orifice size for

the elevations indicated.

Maximum manifold pressure is 3.5 in. w.c. (0.87

kPa) for natural gas and 10 in. w.c. (2.49 kPa)

for LP/Propane gas.

Do not use these appliances if any part has

been under water. Immediately call a qualified,

professional service technician to inspect the

appliance and to replace any parts of the control

system and any gas control which have been

under water.

Ne pas se servir de cet appareil s'il a été plongé

dans l'eau, complètement ou en partie. Appeler

un technicien qualifié pour inspecter l'appareil

et remplacer toute partie du système de con-

trôle et toute commande qui ont été plongés

dans l'leau.

Test gage connections are provided on the front

of the millivolt and electronic gas control valve

(identified OUT for the manifold side and IN for

inlet pressure. A 1/8" NPT test gage connection

is provided on the electronic gas control valve

adjacent to the outlet to the main burner.

Minimum inlet gas pressure to these appli-

ances is 5.0 inches water column (1.24 kPa)

for natural gas and 11 inches water column

(2.74 kPa) for propane for the purpose of input

adjustment.

Maximum inlet gas supply pressure to these

appliances is 10.5 inches water column (2.61

kPa) for natural gas and 13.0 inches water

column (3.23 kPa) for propane.

The appliance must be isolated from the gas

supply piping system (by closing its individual

manual shut-off valve) during any pressure testing

of the gas supply piping system at test pressures

equal to or less than 1/2 psig (3.5 kPa).

The appliance and its individual shut-off valve

must be disconnected from the gas supply

piping system during any pressure testing of

that system at pressures in excess of 1/2 psig

(3.5 kPa).

These appliances must not be connected to a

chimney or flue serving a separate solid fuel

burning appliance.

Table 1

Figure 1

WarninG: FaiLure to coMpLY WitH

tHe instaLLation and operatinG

instructions proVided in tHis

docuMent WiLL resuLt in an iM-

properLY instaLLed and operatinG

appLiance, VoidinG its WarrantY.

anY cHanGe to tHis appLiance

and/or its operatinG controLs

is danGerous. iMproper instaL-

Lation or use oF tHis appLiance

can cause serious injurY or deatH

FroM Fire, Burns, expLosion or

carBon Monoxide poisoninG.

WarninG: cHiLdren and aduLts

sHouLd Be aLerted to tHe Hazards

oF HiGH surFace teMperatures. use

caution around tHe appLiance to

aVoid Burns or cLotHinG iGnition.

YounG cHiLdren sHouLd Be care-

FuLLY superVised WHen tHeY are in

tHe saMe rooM as tHe appLiance.

WarninG: do not pLace cLotHinG

or otHer FLaMMaBLe MateriaLs

on or near tHis appLiance.

aVertisseMent: surVeiLLer Les

enFants. Garder Les VêteMents,

Les MeuBLes, L'essence ou autres

LiQuides à Vapeur inFLaMMaBLes

Loin de L'appareiL.

l

e

d

o

M

.

o

N

e

z

i

s

e

c

if

ir

O

n

o

it

a

v

e

l

E

t

e

e

F

)

s

r

e

t

e

m

(

.t

a

N

.

p

o

r

P

5

3

V

D

L

E

8

3

#

3

5

#

0

0

5

4

-

0

)

2

7

3

1

-

0

(

0

4

V

D

L

E

7

3

#

"

2

6

0

.

0

5

4

V

D

L

E

6

3

#

2

5

#

Any safety guard or screen removed for ser-

vicing the appliance must be replaced prior to

operating the appliance.

Piezo Ignitor

Gas

Supply

Line

ON/OFF

Switch

ON

OFF

Shut-Off Valve

(Orientation

As Shown)

Gas Valve

Air Shutter

Adjustment Arm

Gas Line Access Plate Not Installed

At The Factory. It Is Included In

The Installation Instruction Bag.

Right Corner Post

Advertising