NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

The adjustment rod, arm and associated adjust-

able air shutter is patented technology. Flame

adjustments can be made quickly and accurately

to taste without the need of disassembling the

appliance and waiting for 30 minutes after each

adjustment.

Front Glass enclosure panel, removal

and installation

These are direct-vent appliances. They are

designed to operate only when the front glass

enclosure panel is installed. Generally the front

glass enclosure panel should not be removed ex-

cept to gain access to the components within the

firebox, and the appliance may only be operated

without the front glass enclosure panel in place

for very brief periods of time during appliance

checkout and adjustment. Be sure that the flame

appearance will be diminished while the front

glass enclosure panel is removed.

refer to Figure 4 and remove the front glass

enclosure panel as follows:

. Remove the bottom compartment door by

lifting and pulling it towards the front of the

fireplace.

ensure tHat tHe Front GLass paneL is in

pLace and seaLed durinG adjustMent.

Sooting is caused by incomplete combustion

in the flames and a lack of combustion air

entering the air shutter opening. To achieve a

warm yellow to orange flame with an orange

body that does not soot, the shutter opening

must be adjusted between these two extremes.

No smoke or soot should be present.

To adjust the flame, move the adjustment arm

(located in the lower control area) up or down

to increase or reduce the air shutter opening,

respectively. position the air shutter to the

factory setting as shown in Figure 5 on page

7. Allow the burner to operate for at least 15

minutes. Observe the flame continuously. If it

appears weak or sooty as previously described,

adjust the air shutter by pushing or pulling on

the adjustment rod until the flame appearance

is as desired.

Figure 4

Burner adjustments

The following paragraphs address burner

adjustment concerns and procedures.

When satisfied that the appliance operates

properly, proceed to finish the installation. Leave

the control knob in “ON” position and turn the

remote switch “OFF.” Close the lower control

compartment door.

Flame appearance and sooting

Proper flame appearance is a matter of taste.

Generally most people prefer the warm glow of

a yellow to orange flame. Appliances operated

with air shutter openings that are too large will

exhibit flames that are blue and transparent.

These weak, blue and transparent flames are

termed anemic. If the air shutter opening is too

small sooting may develop.

Propane models may exhibit a flame pattern

that may candle or appear stringy. If this is

problematic or persists as the appliance is

continually operated, adjust the air shutter

closed as described in the previous paragraphs.

Operate the appliance for a period of time as the

effect diminishes, ensuring that the appliance

does not develop sooty flames.

Burner adjustment

If the logs are properly positioned and sooting

conditions exist, the air shutter opening on the

main burner tube should be adjusted. Normally,

the more offsets in the vent system, the greater the

need for the air shutter to be opened further.

. Retrieve the glass door frame. Visually

inspect the gasket on the backside of the panel.

The gasket surface must be clean, free of ir-

regularities and seated firmly.

2. Position the door frame in front of the firebox

opening and engage the top flange over the lip

at the top of the firebox opening.

3. Swing the door down and back. Ensure the

gasket seats evenly as the door draws shut. Engage

the Vee-flange at the bottom of the door with the

latches and close the latches to secure the door.

. Reinstall the bottom compartment door by hook-

ing it over the slots on the two corner posts.

to install the front glass enclosure panel,

proceed as follows:

caution: tHe adjustMent arM and

nearBY appLiance surFaces are Hot.

exercise caution to aVoid injurY WHiLe

adjustinG FLaMe appearance.

WarninG: do not operate ap-

pLiance WitH tHe GLass Front

reMoVed, cracKed or BroKen.

repLaceMent oF tHe GLass sHouLd

Be done BY a Licensed or QuaLiFied

serVice tecHnician.

WarninG: HandLe tHis GLass WitH ex-

treMe care! teMpered GLass is sus-

ceptiBLe to daMaGe – do not scratcH

or HandLe rouGHLY WHiLe reinstaLL-

inG tHe GLass door FraMe.

WarninG: no not atteMpt to suB-

stitute tHe MateriaLs used on

tHis door, or repLace cracKed or

BroKen GLass WitH anY MateriaLs

otHer tHan tHose proVided BY tHe

appLiance ManuFacturer.

tHe GLass door oF tHis appLi-

ance Must onLY Be repLaced as a

coMpLete unit as proVided BY tHe

ManuFacturer. do not atteMpt

to repLace BroKen, cracKed or

cHipped GLass separateLY.

WarninG: air sHutter adjustMent

sHouLd onLY Be perForMed BY a

QuaLiFied proFessionaL serVice

tecHnician.

Door

Assembly

Gas Line Access Panel

Bottom Panel

Blower Access

Plate

Sooting is indicated by black puffs developing

at the tips of very long orange flames. Sooting

results in black deposits forming on the logs,

appliance inside surfaces and on exterior sur-

faces adjacent to the vent termination.

2. Locate the two (2) latches at the top of the

control compartment and disengage them from

the floor frame bottom Vee-flange, pulling down

on their handles to open them.

3. Swing the bottom of the door out and raise

it slightly to lift the top flange of the door frame

away from the appliance.

Refer to the maintenance schedule for mainte-

nance tasks, procedures, periodicity and by whom

they should be performed. Always verify proper

operation of the appliance after servicing.