NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Figure 9

Figure 10

Glowing embers (rockwool) and Volcanic

stones placement

Refer to the detailed glowing embers placement

instructions provided in the LoG pLaceMent

Guide accompanying this document.

ceramic panel placement

Refer to the detailed ceramic panel placement

instructions provided in the LoG pLaceMent

Guide accompanying this document.

Millivolt appliance checkout

The pilot flame should be steady, not lifting

or floating. Flame should be blue in color with

traces of orange at the outer edge.

The top 3/8" (10 mm) at the pilot generator

(thermopile) and the top 1/8" min (tip) of the

quick drop out thermocouple should be engulfed

in the pilot flame. The flame should project 1"

(25 mm) beyond the hood at all three ports.

See Figure 9. To light the burner, refer to the

lighting instructions on pages 12 and 13.

accessorY coMponents

remote control system (standard)

H029

rcL

standard remote control system

The Model RCL (Standard) Remote Control

System, features a simple On/Off control func-

tion for the fireplace. This model includes a

hand-held transmitter, a remote receiver with

wall-mount coverplate and all hardware required

to install the unit. The remote receiver can be

wall or hearth mounted.

deluxe remote control system

The Model RCL-T (Deluxe) Remote Control

System has all of the features of the standard

system along with an added easy to read LCD

screen which presents access to many enhance-

ments, including; battery power level indicator,

timer, mode of operation, thermostatic display

including room temperature in either metric

of English units, flame indicator and clock.

Fully programmable, the Model RCL-T allows

for command over nearly all operational and

temperature variables, using the hand held

remote control transmitter.

remote control system (deluxe)

H025

rcL-t

Forced air Blower Kit

single speed

H678

LBLK-00

Forced air Kit

The LBLK-100 blower provides constant velocity

forced air circulation.

MILLIVOLT

Thermocouple

Hood

Ignitor Rod

3/8" Min

(9 mm)

Thermopile

Pilot

Nozzels

ELECTRONIC

Pilot

Hood

Sensor

Ignitor

touch-up paint (Black) Kit

70K99

FtpK-B

touch-up paint Kit

Repair of minor scratches and discoloration of

the appliance charcoal painted surfaces may be

accomplished with the touch-up paint kit.

installing optional decorative style View

doors

Decorative Style View doors are optional with

these fireplaces. When installing Style View

doors on any of these models remove, retain

and store away the bottom panel from the

control compartment accessway. The bottom

of the Style View doors provide coverage for

this area. If the doors are installed, the unit

mounted On/Off switch, if used, must be re-

located to the bracket provided with the door.

Refer to the detailed instructions provided with

the doors.

electronic appliance checkout

To light the burner, refer to the lighting instruc-

tions on page 14 and 15. Ensure the ignitor

lights the pilot. The pilot flame should engulf

the flame sensor as shown in Figure 10.

With proper care and maintenance, your appli-

ance will provide many years of enjoyment. If

you should experience any problem, first refer

to the trouble shooting guide in this manual.

If problem persists, contact your Lennox

distributor.