2.7 Technical Specifications

Table 3 - Technical Specs

The transceiver used in the NET485 is intended for balanced data transmission and complies with both EIA
Standards RS-485 and RS-422. It contains a differential line driver and a differential line receiver, and is
suitable for half-duplex transfer. The input impedance is 19KOhm allowing up to 50 transceivers to be
connected on the bus.

Category

Description

CPU

DSTni-EX 186 CPU, 256 KB zero wait state SRAM
2048KB Flash, 16KB Boot ROM, 1024KB SRAM

Firmware

Upgradeable via TFTP

Reset Circuit

Reset In is low active. (Software reset only)

Serial Interface

RS422/485. Baudrate software selectable (300 to 921600)

Serial Line Formats

7 or 8 data bits, 1-2 Stop bits, Parity: odd, even, none

Network Interface

RJ45 Ethernet 10Base-T or 100Base-TX (Auto-sensing)

Compatibility Ethernet:

Version 2.0/IEEE 802.3

Protocols Supported

ARP, UDP, TCP, Telnet, ICMP, SNMP, DHCP, BOOTP, TFTP, Auto IP, SMTP, and
HTTP

Power Input

8VDC to 24VDC, approximately 200ma.

LEDs

10Base-T & 100Base-TX Activity, Full/half duplex.

Management

Internal web server, SNMP (read only) Serial login, Telnet login

Security

Password protection, Locking features, optional Rijndael 128-bit encryption

Internal Web Server

Serves static web pages and Java applets

Weight

1.7oz

Material Case:

Flame Retardant

Temperature

Operating range: -40°C to +85°C (-40°F to 185°F) High performance mode has an
upper temperature limit of 75°C.

Relative Humidity

Operating: 5% to 95% non-condensing

Warranty 1-year

limited

warranty

Included Software

Windows™ 98/NT/2000/XP based Device Installer configuration software, Windows™
based Comm Port Redirector.

EMI Compliance

Radiated & conducted emissions - complies with Class B limits of EN 55022:1998
Direct & Indirect ESD - complies with EN55024:1998
RF Electromagnetic Field Immunity - complies with EN55024:1998
Electrical Fast Transient/Burst Immunity - complies with EN55024:1998
Power Frequency Magnetic Field Immunity - complies with EN55024:1998
RF Common Mode Conducted Susceptibility - complies with EN55024:1998