Connection settings - udp, 2 connection settings - udp -17 – Lantronix Device Server MSS 485 User Manual

Page 39

Advertising
background image

Device Installer

3.7.2 Connection Settings - UDP

To configure a channel’s UDP settings:

1. On the main menu, click Connection. The Connection Settings window for the selected channel displays.

2. In the available fields, enter or modify the following information:

Connect Protocol

Protocol

Select UDP from the drop-down menu.

Datagram Mode

Datagram Type

Configures the remote IP or network broadcast address and the remote
port. Enter 01 for directed or broadcast UDP.

Accept Incoming

Select Yes to accept incoming UDP datagrams.

Local Port

Enter the local port number.

Remote Port

Enter the port number of the remote device.

Remote Host

Enter the IP address of the remote device.

Device Address Table

The table is enabled when Datagram Type is set to FD. Enter
values between 1 and 255 to identify units on the local
network of device servers.

Note: Lantronix Tech Support supports Datagram type 01.
Datagram Type FD is for OEM use.

3. When you are finished, click the OK button.

4. On the main menu, click Apply Settings.

NET485 User Guide

3-17

Advertising