First, check that the wind-cups and the wind-vane can rotate freely
before fixing the unit. For correct and accurate readings, it is important
to mount the sensor so that the front (marked E) is pointing in East-
West direction. The wind sensor should now be mounted using the
screw or cable tie provided onto a solid wall/ panel mast or mast to
allow the wind to travel around the sensor unhindered from all directions
(ideal mast size should be from diameter 0.62” to 1.29” (16mm to
33mm). Do not over tighten.
Once the wind sensor is fixed onto the mast, connect the cable to the
corresponding thermo-hygro sensor socket so that operating power
supply can be received and data can be transmitted to the base station.
Secure cord from blowing. Do not use staples. Using PVC pipe or metal
as a mast may cause static. Wood is recommended.

The Rain Sensor









For best results, the rain sensor should be securely mounted onto a
horizontal surface about 39.37” (1 meter) above the ground (or higher)
and in an open area away from trees or other coverings where rainfall
may be reduced causing inaccurate readings.

When securing into place, check that rain excess will not collect and
store at the base of the unit but can flow out between the base and the
mounting surface (test by pouring clean water).

After mounting the rain sensor and placing battery, the rain sensor is
now operable. For testing purposes, very slowly pour a small amount of
clean water into the rain sensor funnel. The water will act as rainfall and
will be received and displayed at the base station i.e. when the reading
interval is reached.

Note:
You will need to be able to access your rain gauge periodically to clean
debris and possible insect nests. Please keep this in mind when
mounting.

LA CROSSE TECHNOLOGY SENSOR EXTENSION CABLE

Horizontal panel

34


When you require additional length to properly mount your sensor, you
can use a La Crosse Technology extension cable. The extension cable
is 32 feet in length and comes with the appropriate connecter attached,
Please visit your local retailer or www.greatbigoutlet.com to purchase.

Phone cable and connections have much more resistance than our
extension cable and is not recommended for use. Using phone
cable/connection may damage your sensors.

Note:
Using extension cables will shorten battery life.

Warning:
Never cut, splice, shorten or modify your sensor cables or extension
cables. Doing so may damage your sensors and will Void you Warranty.

CARE AND MAINTENANCE:

Extreme temperatures, vibration and shock should be avoided as
these may cause damage to the unit and give inaccurate
forecasts and readings.

Precautions shall be taken when handling the batteries. Injuries,
burns, or property damage may be resulted if the batteries are in
contact with conducting materials, heat, corrosive materials or
explosives. The batteries shall be taken out from the unit before
the product is to be stored for a long period of time.

Immediately remove all low powered batteries to avoid leakage
and damage. Replace only with new batteries of the
recommended type.

When cleaning the display and casings, use a soft damp cloth
only. Do not use solvents or scouring agents as they may mark
the LCD and casings.

Do not submerge the unit in water.

Special care shall be taken when handling a damaged LCD
display. The liquid crystals can be harmful to user's health.

Do not make any repair attempts to the unit. Return them to their
original point of purchase for repair by a qualified engineer.
Opening and tampering with the unit may invalidate their
guarantee.

Never touch the exposed electronic circuit of the device as there
is a danger of electric shock should it become exposed.

Do not expose the units to extreme and sudden temperature
changes, this may lead to rapid changes in forecasts and
readings and thereby reduce their accuracy.

SPECIFICATIONS:

Temperature measuring range:

35

Indoor

: 32°F to +140°F with 0.2°F resolution

0ºC to +59.9ºC with 0.1ºC resolution

(“OF.L” displayed if outside this range)

Outdoor / dew point :

-40°F to +140°F with 0.2°F resolution

-40ºC to +59.9ºC with 0.1ºC resolution

(“OF.L” displayed if outside this range)

Relative humidity measuring range:
Outdoor

: 1% to 99% with 1% resolution

(“- -” displayed if < 1%, "99" displayed if

≥ 99%)

Wind speed/ gust :

0 to 111.8 mph (0 to 50 m/s)

(displayed "OF.L" when > 111.8 mph; 50m/s)

Wind chill/ dew point:

-40°F to +140°F (-40ºC to +59.9ºC)

(displayed "OF.L" if outside this)

Relative pressure pre-set range :

27.17 to 31.90 inHg (919 to

1080 hPa)

24h rainfall

:

0" to 39.36" (0 to 999.9 mm)

(displayed "OF.L" when > 999.9mm)

Total rainfall

:

0" to 393.6" (0 to 9999 mm)

(displayed "OF.L" when > 9999mm)

Outdoor data reception

:

every 4.5 seconds (from thermo-hygro

transmitter)

every 6.25 seconds (from rain sensor)

Air pressure checking interval: every 15 seconds
Transmission range

:

up to 330 feet (100 meters) in open

space
Power consumption:
Weather Center

:

3 x AA, IEC LR6, 1.5V

Thermo-hygro transmitter :

2 x AA, IEC LR6, 1.5V

Rain sensor

:

2 x AAA, IEC LR3, 1.5V

Battery life

:

approximately 24 months (Alkaline
batteries recommended)

Dimensions (L x W x H):
Weather Center

: 4.59” x 0.94” x 7.01”

(116.8 x 24 x 178.1mm)

Thermo-hygro transmitter : 2.25” x 2.44” x 6.18”

(57.3 x 62 x 157mm)

Wind sensor

: 9.84” x 5.74” x1087”

(250 x 145.9 x 276.2mm)

Rain sensor

: 5.67” x 2.15” x3.46”

(144 x 54.6 x 88mm)

LIABILITY DISCLAIMER

The electrical and electronic wastes contain hazardous
substances. Disposal of electronic waste in wild country and/or in
unauthorized grounds strongly damages the environment.

Please contact your local or/and regional authorities to retrieve
the addresses of legal dumping grounds with selective collection.

36

All electronic instruments must from now on be recycled. User
shall take an active part in the reuse, recycling and recovery of
the electrical and electronic waste.

The unrestricted disposal of electronic waste may do harm on
public health and the quality of environment.

As stated on the gift box and labeled on the product, reading the
“User manual” is highly recommended for the benefit of the user.
This product should not be thrown in general rubbish collection
points.

The manufacturer and supplier cannot accept any responsibility
for any incorrect readings and any consequences that occur
should an inaccurate reading take place.

This product is designed for use in the home only as indication of
the temperature.

This product is not to be used for medical purposes or for public
information.

The specifications of this product may change without prior notice.

This product is not a toy. Keep out of the reach of children.

No part of this manual may be reproduced without written
authorization of the manufacturer.


WARRANTY INFORMATION

La Crosse Technology, Ltd provides a 1-year limited warranty on this

product against manufacturing defects in materials and workmanship.

This limited warranty begins on the original date of purchase, is valid

only on products purchased and used in North America and only to the

original purchaser of this product. To receive warranty service, the

purchaser must contact La Crosse Technology, Ltd for problem

determination and service procedures. Warranty service can only be

performed by a La Crosse Technology, Ltd authorized service center.

The original dated bill of sale must be presented upon request as proof

of purchase to La Crosse Technology, Ltd or La Crosse Technology,

Ltd’s authorized service center.

La Crosse Technology, Ltd will repair or replace this product, at our

option and at no charge as stipulated herein, with new or reconditioned

parts or products if found to be defective during the limited warranty

period specified above. All replaced parts and products become the

property of La Crosse Technology, Ltd and must be returned to La

Crosse Technology, Ltd. Replacement parts and products assume the

remaining original warranty, or ninety (90) days, whichever is longer.

La Crosse Technology, Ltd will pay all expenses for labor and materials

for all repairs covered by this warranty. If necessary repairs are not

covered by this warranty, or if a product is examined which is not in

need or repair, you will be charged for the repairs or examination. The

owner must pay any shipping charges incurred in getting your La

Advertising
This manual is related to the following products: