LG LA090HP User Manual

Page 13

Advertising
background image

10

25' maximum

8' minimum
12' maximum

OIL TRAP

INDOOR UNIT

OUTDOOR UNIT

***Each system is pre-charged with enough refrigerant to charge 25 ft. of line and the interior unit.

NOTE: Systems having the outdoor unit mounted above the indoor unit (e.g. basement
installations) have the following additional requirement:
For systems with maximum elevation of 25 ft. (see Figure A), refrigerant lines must be oil
trapped between 8 ft. and 12 ft. of elevation.
For systems with elevation of greater than 25 ft. Refrigerant lines must be oil trapped at least
every 12 ft. of elevation.

* Each system should have a 6-8 inch inverted trap at the condensing unit if mounted above

indoor unit.

Figure A.
Example: 25 ft. maximum elevation.

ART COOL MINI-SPLIT SINGLE ZONE

ELECTRICAL & REFRIGERATION

QUICK REFERENCE

NOTE: Recommend shielded cable for low voltage wiring.
Please see local electrical codes for proper wire specifications.

All equipment single phase.

*Minimum Circuit Ampacity

**Maximum Overcurrent Protection

Wire Size

Minimum AWG

14-3

Indoor/Outdoor Connecting Cable Shielded

18-4

Refrigerant Line Specifications***

Electrical Specifications

Type

Model

BTUs

Voltage

Rated Amps

MCA*

MOP**

ARTCOOL ™

Indoor

Outdoor

A/C

LA090CP

9,000

36V DC

115

7.2

15

15

A/C

LA120CP

12,000

36V DC

115

9.3

15

20

A/C

LA121CPM

11,500

36V DC

115

10.5

15

20

A/C

LA180CP

18,000

36V DC

230/208

9.8

15

20

H/P

LA090HP

9,000

36V DC

115

7.2

15

20

H/P

LA120HP

12,000

36V DC

115

9.3

15

20

H/P

LA121HPM

11,500

36V DC

115

10.5

15

20

Type

Model

BTUs

Pipe Size

Additional

Max. Pipe

Max.

ARTCOOL ™

Liquid

Suction

Refrigerant

Length

Elevation

A/C

LA090CP

9,000

1/4"

3/8"

0.21 oz./ft.

50'

25'

A/C

LA120CP

12,000

1/4"

1/2"

0.21 oz./ft.

50'

25'

A/C

LA121CPM

11,500

1/4"

1/2"

0.21 oz./ft.

50'

25'

A/C

LA180CP

18,000

1/4"

1/2"

0.21 oz./ft.

100'

50'

H/P

LA090HP

9,000

1/4"

3/8"

0.21 oz./ft.

50'

25'

H/P

LA120HP

12,000

1/4"

1/2 "

0.21 oz./ft.

50'

25'

H/P

LA121HP

11,500

1/4"

1/2 "

0.21 oz./ft.

50'

25'

Single Zone

Single Zone

Advertising
This manual is related to the following products: