Diagrams, Dc-655 – Lincoln Electric DC-655 IM602-A User Manual

Page 37

Advertising
background image

F-1

DIAGRAMS

DC-655

F-1

N.C.

Tape up bolted connection if lead #

21

is extended

.

N.D.

C

onnect the control cable ground lead to the frame terminal

marked near the power source terminal strip

.

The power

source grounding terminal (marked and located near the power

source input power connections) must be properly connected to

electrical ground per the power source operating manual

.

N.E.

If an optional remote voltage control is used

, connect it to

this terminal strip

.

N.A.

W

elding cables must be of proper capacity for the current and

duty cycle of immediate and future applications

.

S

ee

LN-

7

O

perating

M

anual for proper sizes

.

N.B.

If

LN-

7 is equipped with a meter kit

, extend

LN-

7 control cable

suitable for the installation

.

A

n

S16586-

[LENGTH

] remote

voltage sensing work lead may be ordered for this purpose

.

C

onnect it directly to the work piece independent of the welding

work cable connection

.

For convenience

, this extended #

21

lead

should be taped to the welding work lead

. (

If the length of

welding work cable is short

, less than

25

feet

, and connections

can be expected to be reliable

, then control cable lead #

21

does

not need to be extended and can be directly connected to

terminal #

21

on the terminal strip

.

N

ote that this is not the

preferred connection because it adds error to the

LN-

7 voltmeter

A

bove diagram shows electrode connected positive

.

To change polarity

,

turn power off

, reverse the electrode and work leads at the power

41

423

1

32

75

76

77

NEGATIVE

POSITIVE

32 31 2 4

GND

21

N.A.

N.D.

ELECTRODE

CABLE

TO

WIRE

FEED

UNIT

TO

WORK

POWER

SOURCE

N.E.

N.F.

reading

.)

N.F.

If lead #

21

is to be connected to

the terminal strip

,

connect to the #

21

terminal that matches

work polarity

.

This

connection must be changed whenever the

electrode polarity is

changed

.

Only qualified persons should install

, use or

service this machine

.

Do not operate with covers removed

.

Disconnect power source before

servicing

.

Do not touch electrically live parts

.

LN-

7

TO

INPUT

CABLE

PLUG

LN-

7

CONTROL

CABLE

21

-

21

FOR

CONTROL

CABLE

WITH

14

PIN

MS-TYPE

PLUG

CONNECTOR

OR

FOR

CONTROL

CABLE

WITH

TERMINAL

STRIP

LEAD

CONNECTORS

CONTROL

CABLE

S22

97

6

source and position the switch on wire feeder (if equipped )

to proper polarity

. A

lso refer to note

N.F.

N.B.

&

N.C.

14-PIN

RECEPTACLE

lead #

21

from control cable with terminal strip connectors or from

14-

pin receptacle using #

14

AWG

or larger insulated wire physically

21

+

REMOTE

VOLTAGE

SENSING

LEAD

10-30-

98F

N.G.

N.G.

Illustration does not necessarily represent actual position of

for more information

.

CONNECTION OF LN-7 TO THE CV-655, DC-655 OR DC-600 POWER SOURCE

appropriate output studs

. R

efer to power source operating manual

For proper setting of switches on power source

,

see power source operating manual

.