Diagrams, Dc-655 – Lincoln Electric DC-655 IM602-A User Manual

Page 39

Advertising
background image

F-3

DIAGRAMS

F-3

DC-655

A

bove diagram shows electrode connected positive

.

To change polarity

,

turn power off

, reverse the electrode and work leads at the power

NEGATIVE

POSITIVE

32 31 2 4

GND

21

N.A.

N.D.

ELECTRODE

CABLE

TO

WORK

POWER

SOURCE

Only qualified persons should install

, use or

service this machine

.

Do not operate with covers removed

.

Disconnect power source before

servicing

.

Do not touch electrically live parts

.

CONTROL

BOX

21

FOR

CONTROL

CABLE

WITH

14

PIN

MS-TYPE

PLUG

CONNECTOR

OR

FOR

CONTROL

CABLE

WITH

TERMINAL

STRIP

LEAD

CONNECTORS

CONTROL

CABLE

S22

97

8

N.B.

&

N.C.

14-PIN

RECEPTACLE

75

76

77

remote voltage sensing work lead may be ordered for this purpose

.

If lead #

21

is to be connected to

the terminal strip

,

connect to the #

21

terminal that matches

work polarity

.

This

connection must be changed whenever the

electrode polarity is

changed

.

N.A.

W

elding cables must be of proper capacity for the current and

duty cycle of immediate and future applications

.

C

onnect it directly to the work piece keeping it electrically

separate form the welding work lead circuit and connection

.

For

convenience

, this extended #

21

lead should be taped to the

welding work lead

. (

If the length of work lead circuit is

short

, and connections can be expected to be reliable

, then

control cable lead #

21

does not need to be extended and can be

directly connected to terminal #

21

on the terminal strip

.

N

ote

that this is not the preferred connection because it adds error

N.D.

C

onnect the control cable ground lead to the frame terminal

marked near the power source terminal strip

.

The power

source grounding terminal (marked and located near the power

source input power connections) must be properly connected to

electrical ground per the power source operating manual

.

to the wire feeder voltmeter reading

.)

N.F.

source

.

Reverse the leads on the back of the ammeter and voltmeter

in the automatic control box

.A

lso refer to note

N.F.

TO

AUTOMATIC

E

Q

UIPMENT

TO

AUTOMATIC

CONTROL

CABLE

physically suitable for the installation

.

A

n

S16586-

[LENGTH

]

41

423

1

32

75

76

77

N.F.

21

-

21

+

REMOTE

VOLTAGE

SENSING

LEAD

N.C.

Tape up bolted connection if lead #

21

is extended

.

N.E.

If a variable voltage board is present in the automatic controls

,

the jumper lead on the

VV

board must be connected to pin "

L" to

permit the inch down button to operate

.

This jumper

, however

,

will disable the cold starting/autostop feature of the automatic

controls

, permitting only hot starting techniques to be used

.

or from

14-

pin receptacle using #

14

AWG

or larger insulated wire

N.B.

E

xtend lead #

21

from control cable with terminal strip connectors

10-30-

98F

N.G.

Illustration does not necessarily represent actual position of

manual for more information

.

N.G.

CONNECTION OF NA-3, LT-5 OR LT-7 TO THE CV-655, DC-655 OR DC-600 POWER SOURCE

appropriate output studs

.

R

efer to power source operating

For proper setting of switches on power source

,

see power source operating manual

.