Diagrams, Dc-655 – Lincoln Electric DC-655 IM602-A User Manual

Page 38

Advertising
background image

F-2

DIAGRAMS

F-2

DC-655

N.C.

Tape up bolted connection if lead #

21

is extended

.

N.D.

C

onnect the control cable ground lead to the frame terminal

marked near the power source terminal strip

.

The power

source grounding terminal (marked and located near the power

source input power connections) must be properly connected to

electrical ground per the power source operating manual

.

N.A.

W

elding cables must be of proper capacity for the current and

A

bove diagram shows electrode connected positive

.

To change polarity

,

turn power off

, reverse the electrode and work leads at the power

NEGATIVE

POSITIVE

32 31 2 4

GND

21

N.A.

N.D.

ELECTRODE

CABLE

TO

WIRE

FEED

UNIT

TO

WORK

POWER

SOURCE

N.E.

Only qualified persons should install

, use or

service this machine

.

Do not operate with covers removed

.

Disconnect power source before

servicing

.

Do not touch electrically live parts

.

CABLE

21

FOR

CONTROL

CABLE

WITH

14

PIN

MS-TYPE

PLUG

CONNECTOR

OR

FOR

CONTROL

CABLE

WITH

TERMINAL

STRIP

LEAD

CONNECTORS

CONTROL

CABLE

S22

977

source and position the switch on wire feeder (if equipped )

to proper polarity

. A

lso refer to note

N.F.

N.B.

&

N.C.

14-PIN

RECEPTACLE

A

B

C

N.E.

If using an older

LN-8

control cable: connect lead #7

5 to #7

5 on

terminal strip

, connect lead #7

6 to #7

6 on terminal strip

, connect

lead #77 to #77 on the terminal strip

.

the #

21

terminal that matches work polarity

. T

his connection must be

changed whenever the electrode polarity is changed

.

N.G.

I

f lead #

21

is to be connected to the terminal strip

, connect to

N.F.

The

LN-

9 voltage control jumpers must be connected as follows

(refer to

LN-

9

O

perating

M

anual):

W

hite jumper on voltage board to pin "

S

"

.

B

lue jumper on voltage board (later units only)

,

or on start board (earlier units)

, to pin "

B

".

remote voltage sensing work lead may be ordered for this purpose

.

N.B.

E

xtend lead #

21

from control cable with terminal strip connectors or

from

14-

pin receptacle using #

14

AWG

or larger insulated wire

duty cycle of immediate and future applications

.

C

onnect it directly to the work piece keeping it electrically

convenience

, this extended #

21

lead should be taped to the

welding work lead

. (

If the length of work lead circuit is

short

, and connections can be expected to be reliable

, then

control cable lead #

21

does not need to be extended and can be

directly connected to terminal #

21

on the terminal strip

.

N

ote

that this is not the preferred connection because it adds error

separate from the welding work lead circuit and connection

.

For

to the wire feeder voltmeter reading

.)

physically suitable for the installation

.

A

n

S16586-

[LENGTH

]

TO

LN-8

OR

LN-

9

CONTROL

N.F.

INPUT

CABLE

PLUG

41

423

1

32

75

76

77

N.E.

N.G.

21

-

21

+

REMOTE

VOLTAGE

SENSING

LEAD

10-30-

98F

N.H.

Illustration does not necessarily represent actual position of appropriate

output studs

.

R

efer to power source instruction manual for more info

.

N.H.

CONNECTION OF LN-8 OR LN-9 TO THE CV-655, DC-655 OR DC-600 POWER SOURCE

For proper setting of switches on power source

,

see power source operating manual

.