Bar Code

2-41

Draft document

Barcode Control Flag

The control flag is made up of 8 bits as follows:

Setup Barcode Data

This command sets the barcode data on the current printing position.

Model

Dec

Hex

Vertical Pitch

all barcodes except
Post-Net

a

24 wire (259X)

12

0C

1/180 inch

9 wire (248X)

30

1E

1/72 inch

Model

Dec

Hex

long bar height

short bar height

Post-Net

b

24 wire (259X)

288

120

24/180 inch

8/180 inch

9 wire (248X)

270

10E

18/144 inch

6/144 inch

a. All the input data is rounded to the multiple value shown.
b. Barcode height is fixed to the values shown.

Table 2-21: Barcode Control Flags

Bit

Description

Decimal

Hexadecimal Effect

b1

Check Digit

0

00

No check code is generated by the printer.
The host computer should generate the
check code.

1

01

Check code is generated automatically by
the printer.

b2

Human Readable Character

0

00

Print On

1

01

Print Off

b3

EAN-13 (13th digit), UPC-A
(number system character) flag
character position

0

00

Center

1

01

Under

b4-b8

not used

Format

ESC

[

p

n1

n2

d1

d2

Decimal

27

91

112

n1

n2

d1

d2

Hexadecimal 1B

5B

70

n1

n2

d1

d2

Table 2-20: Barcode Length (Continued)