1. Visually inspect the UPS for freight damage. Report damage to the

carrier and your local dealer, Liebert representative or the Liebert

Worldwide Support Group.

2. Decide where to place the PowerSure PSP. Install the UPS indoors

in a controlled environment, where it cannot be accidentally turned

off. Place it in an area of unrestricted airflow around the unit, away

from water, flammable liquids, gases, corrosives, and conductive

contaminants. Maintain a minimum clearance of 100mm (4 in) on

each side of the UPS. Maintain an ambient temperature range of

0°C to 40°C (32°F to 104°F).

3. Plug the PowerSure PSP’s attached 1.8m (6-ft.) power cord into an

AC outlet.

4. Plug any computers and monitors into the orange battery backed up

receptacles.

Other office machines that do not exceed the capacity of the UPS—

inkjet printers, scanners and fax machines—may be plugged into

either of the two (2) black receptacles, which provide surge protec-

tion only.

NOTE
UPS operation in temperatures above 25°C (77°F) reduces

battery life.

185-270V

185-280V

175-270V

175-280V

Refer to user's manual
for voltage setting

Circuit Breaker
Push to Reset

Surge Protection Only

CAUTION: Risk of electric shock.

Refer to bottom of unit for cautionary marking.

Battery Back-up + Surge Protection

Plug this type of equipment into black
receptacles ONLY

Plug computers, monitors & network hubs
into orange receptacles

Inkjet

printer

Scanner

Fax

machine