Perform the upgrade using the TFTP program or the Gateway’s Web-based Utility through its
Administration tab.

14. My DSL service’s PPPoE is always disconnecting.

PPPoE is not actually a dedicated or always-on connection. The DSL ISP can disconnect the service after a
period of inactivity, just like a normal phone dial-up connection to the Internet.

There is a setup option to “keep alive” the connection. This may not always work, so you may need to re-
establish connection periodically.

1. To connect to the Gateway, go to the web browser, and enter http://192.168.1.1 or the IP address of

the Gateway.

2. Enter the username and password, if asked. (The default username and password is admin.)
3. On the Setup screen, select the option Keep Alive, and set the Redial Period option to 30 (seconds)

(this will keep the connection to the ISP and will not disconnect.

4. Click the Save Settings button. Click the Status tab, and click the Connect button.
5. You may see the login status display as Connecting. Press the F5 key to refresh the screen, until you

see the login status display as Connected.

6. Click the Save Settings button to continue.

If the connection is lost again, follow steps 1- 6 to re-establish connection.

15. I can’t access my e-mail, web, or VPN, or I am getting corrupted data from the Internet.

The Maximum Transmission Unit (MTU) setting may need to be adjusted. By default, the MTU is set
automatically.

If you are having some difficulties, perform the following steps:

1. To connect to the Gateway, go to the web browser, and enter http://192.168.1.1 or the IP address of

the Gateway.

2. Enter the username and password, if asked. (The default username and password is admin.)
3. Look for the MTU option, and select Manual. In the Size field, enter 1492.
4. Click the Save Settings button to continue.

If your difficulties continue, change the Size to different values. Try this list of values, one value at a time,
in this order, until your problem is solved:
1462
1400
1362
1300

16. The Power LED flashes continuously.

The Power LED lights up when the device is first powered up. In the meantime, the system will boot up itself
and check for proper operation. After finishing the checking procedure, the LED remains steady to show that
the system is working fine. If the LED continues to flash after this time, the device is not working properly. Try