Lux Products TX9000TS User Manual

Page 10

Advertising
background image

10

W

Y

G

B

O

RC

RH

C

2 WIRE, 24 VOLT AND MILLIVOLT HEAT ONLY SYSTEMS

24 VOLT

HEAT

TRANSFORMER

120 VAC

HEAT

SYSTEM COMMON

OPTIONAL

RC-RH

JUMPER PROVIDED

W

Y

G

B

O

RC

RH

C

3 WIRE HEATING SYSTEM (3RD WIRE FOR FAN)

24 VOLT

HEAT

TRANSFORMER

120 VAC

FAN

HEAT

SYSTEM COMMON

OPTIONAL

RC-RH

JUMPER PROVIDED

W

Y

G

B

O

RC

RH

C

3 WIRE COOLING SYSTEM

24 VOLT

COOL

TRANSFORMER

120 VAC

AC

COMPRESSOR

FAN

SYSTEM COMMON

OPTIONAL

RC-RH

JUMPER PROVIDED

WIRING DIAGRAM
NOTES
(APPLIES TO ALL
DRAWINGS)

* The DASHED wires
are optional depending
on your system type.
* Verify whether “C”,
“X” or “B” wires are
connected to system
common.
* If “B” and “O” are
both present, it is likely
that “B” is a system
common.
* If a “B” wire in your
system is a common,
then connecting it to
the “B” terminal may
cause damage to your
system.
* If “Y” and “C” are
both present, it is likely
that “C” is a system
common.
* Use an optional
common wire to allow
the system to power
your thermostat.

Advertising