• Use UP/DOWN arrows to adjust.
• Touch

EXIT

to return to main display.

6.3. TEMPERATURE CALIBRATION
• From the main menu touch

MENU

.

• SCROLL to CAL TEMP.
• Touch

YES

. CAL TEMP will be visible and

adjustment value will be flashing.
• Use UP/DOWN arrows to adjust offset value.
• Touch

EXIT

to return to the main screen.

6.4. ENERGY USAGE MONITOR
A timer in the unit records your system’s ON time
for each mode of the current day, previous day,
and cumulative total to let you see the effects of
your temperature settings and weather conditions.
• Select HEAT to monitor heating energy usage or
COOL to monitor cooling usage.
To view ENERGY/USAGE
• From the main menu touch

MENU

.

• SCROLL to ENERGY USAGE.
• Touch

YES

. The current day’s ENERGY USAGE

will be displayed.
• Touch

NEXT

to view yesterday’s energy use.

• Touch

NEXT

to advance to total ENERGY usage

since the Monitor was last set to zero.
• Touch

NEXT

to display "000". Touching

NEXT

will toggle between the counter value and "000".
• Touch

YES

to accept the current display value

as the counter value. Use "000" to effect a reset.
• Touch

EXIT

to return to the main screen.

6.5. PROGRAM LOCK
The Program Lock allows the owners/operators to
prevent unauthorized changes to the thermostat’s
settings. When the thermostat is locked, a three
digit code is set (000 to 999). That code must be
re-entered before locked settings can be changed
without performing a hardware reset of the unit.
The status of the lock is indicated by an open or
closed padlock icon.
6.5.1. TO SET CODE
• From the main menu touch

MENU

.

• SCROLL to SET KEYBOARD LOCK.
• Touch

YES

. ENTER OLD CODE and both open

and closed padlock icons will be displayed. The
default code is "000".
• Hold UP/DOWN arrows to count to code
number.
• Touch

YES

. ENTER NEW CODE will appear.

• Hold UP/DOWN arrows to count to code
number (Record Code Number).

• Touch

YES

to accept new code; ENTER OLD

CODE will be visible.
• Touch

EXIT

to return to main display.

6.5.2. TO LOCK SETTINGS
• Touch

OPEN LOCK SYMBOL

on display LOCK

KEY? will appear.
• Touch

YES

. The display will now show a

CLOSED PADLOCK.
6.5.3. TO UNLOCK SETTINGS
• Touch the

CLOSED PADLOCK

. UNLOCK KEY? is

displayed.
• Touch

YES

. ENTER LOCK CODE will be

displayed.
• Hold UP/DOWN arrows to count to code
number.
• Touch

YES

to enter code. The OPEN LOCK

symbol will now be displayed in the display.
If you forget your code and the touch screen is
locked, perform a Hardware Reset to unlock it.
With the touch screen unlocked, you may perform
a Software Reset to reset the code to "000". See
"Hardware Reset" and "Software Reset"
.

7. SETUP OPTIONS

There are Installation Option switches located
inside the thermostat on the rear of its circuit
board. They control the following:
7.1. TIME DISPLAY FORMAT 12/24 SWITCH #1
The position of this switch controls whether the
time is displayed in 12 hour or 24 hour Military
Time format.
7.2. SMART RECOVERY SWITCH #2
Smart Recovery allows your HVAC system to
attempt to recover from a setback period and
reach your desired comfort temperature set point
by the beginning of your programmed comfort
period. This option allows you to choose whether
to use Smart Recovery.
When enabled, Smart Recovery will initiate if:
• Recovery is from an evening setback to
morning comfort or day setback to evening
comfort period.
• In Heat mode the temperature set point of the
comfort period must be higher than the setback
period.
• In Cool mode the temperature set point of the
comfort period must be lower than the setback
period.
• The estimated Smart Recovery time must be
longer than 15 minutes for a Smart recovery to be
initiated.

7