Operation, Changing machine over to feed other wire sizes, Welding with gmaw (mig) – Lincoln Electric WELD-PAK 3200HD User Manual

Page 20: Welding with fcaw (innershield), Overload protection

Advertising
background image

B-6

OPERATION

B-6

The WELD-PAK 3200HD is suitable for .035" alu-
minum wire and .030" stainless wire. Refer to Table
B.1 for recommended procedure settings (requires
K499 Argon Regulator Kit).

TABLE B.1

CHANGING MACHINE OVER TO
FEED OTHER WIRE SIZES

The WELD-PAK 3200HD is shipped from the factory
ready to feed 023

-.025

(0.6 mm) diameter wire. To

operate the WELD-PAK 3200HD with other sizes of
wire, it is necessary to change the contact tip and
change the drive roll over to other sizes. Refer to
Changing the Contact Tip and Changing the Drive
Roll, in the MAINTENANCE section, for specific infor-
mation on these procedures.

WELDING WITH GMAW (MIG)

Shielding Gas

When using the GMAW process, obtain and install a
gas regulator and hose kit; K463 (for CO2) or K499

(Argon mixed) gas regulator and hose kit.

1. For CO2, open the cylinder very slowly. For argon-

mixed gas, open cylinder valve slowly a fraction of
a turn. When the cylinder pressure gauge pointer
stops moving, open the valve fully.

2. If using a regulator with an adjustable flow meter,

close the gun trigger and adjust the flow to give 15

20 cubic ft per hour (CFH) (7

10 I/min) [use 20

25 CFH (10

12 I/min) when welding out of

position or in a drafty location for CO2]. For argon

mixed gas, trigger to release gas pressure, and
adjust the flow to give 25

30 CFH (12

14

I/min).

3. Keep the cylinder valve closed, except when using

the WELD-PAK 3200HD. When finished welding:

a) Close the cylinder valve to stop gas flow.

b) Depress the gun trigger briefly to release the

pressure in the gas hose.

c) Turn off the WELD-PAK 3200HD.

WELDING WITH FCAW (Innershield)

When using the FCAW process, the correct drive roll
and electrode polarity must be used. See Work Cable
Installation in INSTALLATION section for changing
the polarity.

OVERLOAD PROTECTION

Output Overload

The WELD-PAK 3200HD is equipped with a circuit
breaker and a thermostat which protects the machine
from damage if maximum output is exceeded. The cir-
cuit breaker button will extend out when tripped. The
circuit breaker must be manually reset.

Thermal Protection

The WELD-PAK 3200HD has a rated output duty
cycle of 20%. If the duty cycle is exceeded, a thermal
protector will shut off the output until the machine
cools to a reasonable operating temperature. This is
an automatic function of the WELD-PAK 3200HD and
does not require user intervention. The fan continues
to run during cooling.

Electronic Wire Drive Motor Protection

The WELD-PAK 3200HD has built-in protection for
wire drive motor overload.

WELD-PAK 3200HD

Shielding

Voltage/Wire Speed

Process

Welding Wire

Gas

16 ga

14 ga

12 ga

10 ga

MIG DC+

.035 Dia

100% Argon

B-5

D-7

D-9

D-9

4043 Aluminum
Wire

MIG DC+

.035 Dia

100% Argon

B-5

C-7

D-9

D-10

5356 Aluminum
Wire

MIG DC+

.030 Dia

98% Argon/

A-3

C-6

D-7.5

D-7.5

308L Stainless

2% Oxygen

Steel Wire

Advertising