Troubleshooting, Caution – Lincoln Electric WELD-PAK 3200HD User Manual

Page 42

Advertising
background image

E-4

TROUBLESHOOTING

E-4

WELD-PAK 3200HD

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility

for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS
(SYMPTOMS)

Arc is unstable – Poor starting

POSSIBLE AREAS OF
MISADJUSTMENT(S)

1. Check for correct input voltage

to machine – 115vac.

2. Check for proper electrode

polarity for process.

3. Check gun tip for wear or dam-

age and proper size – Replace.

4. Check for proper gas and flow

rate for process. (For MIG only.)

5. Check work cable for loose or

faulty connections.

6. Check gun for damage or

breaks.

7. Check for proper drive roll orien-

tation and alignment.

8. Check liner for proper size.

RECOMMENDED
COURSE OF ACTION

If all recommended possible areas
of misadjustment have been
checked and the problem persists,

Contact your local Lincoln
Authorized Field Service
Facility.

WELDING PROBLEMS

Observe all Safety Guidelines detailed throughout this manual

Advertising
This manual is related to the following products: