Pride Mobility JAZZY 1103 ULTRA User Manual

Page 42

Advertising
background image

42

www.pridemobility.com

Jazzy 1103 Ultra

V I I . O P E R A T I O N

Remote Plus Error Codes

In addition to indicating the current state of battery charge, the battery condition meter can also indicate possible problems
with your power chair’s electrical system. If any of the battery condition meter lights are flashing rapidly, the controller may
be indicating an error. Error codes are displayed as a number of flashing lights. For instance, if the first light is flashing
rapidly, the battery voltage is nearly depleted. The table below identifies the individual error codes, probable causes, and
possible solutions. If you get one of these error codes, contact your authorized Pride Provider.

FLASHING LIGHTS

DIAGNOSIS

SOLUTION

10

High Battery Voltage

Check batteries.

9

Solenoid Brake Fault

Check motor/brake wiring.

8

Possible Controller Fault

See authorized Pride Provider.

7

Possible Joystick Fault

See authorized Pride Provider.

6

Inhibit Active

Unplug charger. Check connections.

5

Right Motor Wiring Fault

Check right motor wiring.

4

Right Motor Disconnected

Check right motor wiring.

3

Left Motor Wiring Fault

Check left motor wiring.

2

Left Motor Disconnected

Check left motor wiring.

1

Low Battery Voltage

Check batteries/battery wiring.

Advertising