Alarm connection, External recording connection, Time adjusting connection – Panasonic WJ-HD200 User Manual

Page 17

Advertising
background image

17

Notes:

• Input rating: Low-active, non-voltage normally open (N.O.) contact
• Output rating for pin # 4 ALARM RECOVERY 1* OUT: High-active with a 200

Ω

resistor pulled up to + 5 V

• Output rating for pin # 7 ALARM 2* OUT: High-active with a 4.7 k

Ω

resistor pulled up to + 12 V.

• Output rating for other pins: Low-active, maximum load capacity of 24 V 100 mA , open-collector with a 4.7 k

Ω

resistor

pulled up to +5 V inside

●

Alarm Connection

There are eight alarm inputs while two outputs are provided with different driving capacity.

●

External Recording Connection

The recording mode will change from the internal timer mode to the external mode (EXT REC MODE) specified in REC SETUP
menu, while turning on the switch.

●

Time Adjusting Connection

Internal timer is calibrated with this input.

Sensor

Door Switch

Alarm Input Terminals

Sinal Ground Terminals

#7 Alarm Output 2 *2

External
Alarm
Reset Switch

#2 Alar

m 1 In

#3 Alar

m 2 In

Relay *1

Alarm Indicator

*1: Use when the indicator exceeds over the drive capacity of the alarm out terminal.
*2: Connect to #6 ALARM OUT 1 when using a low-active device.

#22 External Recording Mode

Master Clock

Non-voltage N.O. Contact
N.O.=Normally Open