400 setup, 410 re-connection, 420 serial/host port – Panasonic WJ-NT204 User Manual

Page 40: 421 serial data port

Advertising
background image

40

■

400 SETUP

Eight of fundamentals are set up for the system.
The menus 430, 460 and 470 will be replaced with dashed
lines when the unit is set to a receiver.

1. The 400 SETUP menu appears when you press the

ENTER button after selecting it in the 000 TOP menu.

2. Select a menu you wish to set up from the 410, 420,

430, 440, 450, 460, 470, and 480, then press the
ENTER. The selected menu appears.

410 RE-CONNECTION

Re-connection is started by the site that is set to ON for this
setting when a call is interrupted during communication.
This setting is applicable only to the system comprising two
WJ-NT204 units, one for TRANSMITTER and the other for
RECEIVER, and when the call has been made with the
Remote Controller WV-CU20. This does not perform in the
multi-site connection.

1. Open the 410 RE-CONNECTION menu.

2. Select either ON or OFF with the direction button. The

default setting is ON.

ON:

Re-connection is enabled.

OFF:

Disabled.

420 SERIAL/HOST PORT

Serial and Host ports are set up in this menu.

1. Open the 420 SERIAL/HOST PORT menu.

2. Select a menu you wish to set up from the 421 and 422,

then press the ENTER. The selected menu appears.

421 SERIAL DATA PORT:

Select this when the system

comprises a Matrix Switcher (WJ-SX550A/B),
Digital Disk Recorder or other PS

•

Data devices.

422 HOST PORT:

Select this when the system con-

nects with a personal computer.

421 SERIAL DATA PORT

The DIP switch #4 on the rear of the unit specifies the
usable serial port from RS-232C or RS-485 (PS

•

Data). The

settings below must be the same among the devices con-
nected in the chain, except the unit #.

1. Open the 421 SERIAL DATA PORT menu.

2. Move the cursor to RATE, then select a Baud rate with

the A or B button.
The default setting is 9600.

4800:

4800 bps (bit per second)

9600:

9600 bps

19200:

19200 bps


410 RE-CONNECTION

RE-CONNECTION : ON OFF

IN COM.STATE,NT204 WILL CONNECT
AGAIN IN CASE OF NETWORK
INTERRUPTION.

←→

:SELECT ESC:PRV


420 SERIAL/HOST PORT

421 SERIAL DATA PORT

↓

422 HOST PORT

↓

↑↓

:MOVE ENT:SELECT ESC:PRV


421 SERIAL DATA PORT

RATE : 4800 9600 19200
DATA BITS: 8 7
STOP BITS: 1 2
PARITY : NONE ODD EVEN

MODE : PSD NORMAL
RS485 UNIT #:002 (002-999)

↑↓

:MOVE

←→

:SELECT ESC:PRV


400 SETUP

410 RE-CONNECTION

↓

420 SERIAL/HOST PORT

↓

430 VIDEO SWITCH SETUP

↓

440 AUDIO

↓

450 VIDEO

↓

460 ALARM

↓

470 SEQ.SCAN SETUP

↓

480 LOCK/MENU PASSWORD

↓

↑↓

:MOVE ENT:SELECT ESC:PRV