Carrier (telco) and user register organization – Paradyne ACCULINK 316x User Manual
Page 100

ACCULINK 316x DSU/CSU
3-58
December 1996
3160-A2-GB22-10
Table 3-11
(2 of 2)
Performance Registers
Register
Totals Description
Interval Description
CSS
The number of Controlled Slip Seconds for the
current interval.
The total number of Controlled Slip Seconds for the
previous 24 hours (maximum value is 255).
StEvnt
Status events register records whether one or
more of the following events have occurred at
least once during the interval. The event is
identified by a letter as follows:
Y – A yellow alarm has been received on
the network interface.
L – Loss Of Signal has occurred on the
network interface.
E – The Excessive Error Rate threshold has
been exceeded.
F – A Frame Synchronization Bit Error has
been detected.
V – A Line Code Violation has been
detected.
none – None of the above events have
occurred.
N/A
Figure 3-35. Carrier (Telco) and User Register Organization