Paradyne ACCULINK 316x User Manual

Page 194

Advertising
background image

ACCULINK 316x DSU/CSU

E-14

December 1996

3160-A2-GB22-10

•

testMonQRSS – Initiates a Monitor QRSS test on
the interface. Supported for the data ports and the
Network T1 interface.

•

testMon511 – Initiates a Monitor 511 test on the
interface. Only supported for the data ports.

•

testSendQRSS – Initiates a Send QRSS test on the
interface. Only supported for the data ports.

•

testSend511 – Initiates a send 511 test on the
interface. Only supported for the data ports.

•

testSendV54Up – Sends a V54 up code to the
remote unit. Only supported for the data ports.

•

testSendV54Down –Sends a V54 down code to the
remote unit. Only supported for the data ports.

•

testSendFT1Up – ends a FT1 up code to the remote
unit. Only supported for the data ports.

•

testSendFT1Down – Sends a FT1 down code to the
remote unit. Only supported for the data ports.

Where these object identifiers are defined as follows:

•

testLoopDTLB – OBJECT IDENTIFIER ::=
[wellKnownTests 2]

•

testMonQRSS – OBJECT IDENTIFIER ::=
[wellKnownTests 3]

•

testMon511 – OBJECT IDENTIFIER ::=
[wellKnownTests 4]

•

testSendQRSS – OBJECT IDENTIFIER ::=
[wellKnownTests 5]

•

testSend511 – OBJECT IDENTIFIER ::=
[wellKnownTests 6]

•

testSendV54Up – OBJECT IDENTIFIER ::=
[wellKnownTests 7]

•

testSendV54Down – OBJECT IDENTIFIER ::=
[wellKnownTests 8]

•

testSendFT1Up – OBJECT IDENTIFIER ::=
[wellKnownTests 9]

•

testSendFT1Down – OBJECT IDENTIFIER ::=
[wellKnownTests 10]

Generic Interface Test Table –
“ifExtnsTestResult” Object
(ifExtnsTestEntry 5)

This object contains the result of the most recently

requested test. Only the following values are supported by
the DSU/CSU.

•

none(1) – No test currently active.

•

inProgress(3) – A test is currently in progress.

•

notSupported(4) – The requested test is not
supported.

•

unAbleToRun(5) – The requested test cannot run
due to the state of the unit.

Generic Interface Test Table –
“ifExtnsTestCode” Object
(ifExtnsTestEntry 6)

This object contains a code which contains more

specific information on the test result. This object is
defined as an INTEGER. Only the following values are
supported by the DSU/CSU.

•

none – No further information is available. Used for
the send pattern/code and loopback tests.

•

inSyncNoBitErrors – A monitor pattern (QRSS or
511) test has synchronized on the pattern and has
not detected any bit errors.

•

inSyncWithBitErrors – A monitor pattern (QRSS or
511) test has synchronized on the pattern and has
detected bit errors.

•

notInSync – A monitor pattern (QRSS or 511) test
has not synchronized on the requested pattern.

Where these object identifiers are defined as follows:

•

wellKnownCodes – OBJECT IDENTIFIER ::=
[ifExtensions 5]

•

none – OBJECT IDENTIFIER ::=
[wellKnownCodes 1]

•

inSyncNoBitErrors – OBJECT IDENTIFIER ::=
[wellKnownCodes 2]

•

inSyncWithBitErrors – OBJECT IDENTIFIER ::=
[wellKnownCodes 3]

•

notInSync – OBJECT IDENTIFIER ::=
[wellKnownCodes 4]

Advertising