Standard Features MegaTherm MT (500-5000)

MODEL

MT-POOL

REVISION
P- PUMP

500-1825

A- 2000-5000

HEAT EXCHANGER

C-GLASS LINED/COPPER
N-GLASS LINES/CU-NI
K-BRONZE/COPPER
S-BRONZE/CU-NI

VERSION

1-8 TUBE
B-10 TUBE
C-18 TUBE

FUEL

N-NATURAL
P-PROPANE

IGNITION
04- SPARK 110V
09- SPARK 24V

(500-1825)

18- SPARK 24V

(2000-5000)

16- STND. PILOT

SIZE MBTU/h

0500

2000

0600

2200

0715

2450

0850

2800

1010

3050

1200

3200

1430

3500

1670

3600

1825

4000
4050
4500
5000

C

FIRING MODE

C-STD. ON/OFF

OPTIONS
XX- STANDARD UNIT
FX- FM CODE
HL- HIGH + LOW GAS SWITCHES
JD- CSD1 + IRI CODE PACKAGE
JX- CSD-1
LC- L.W.C.O. + 100% LOCKOUT
LW-LOW WATER CUT OFF
MX- MINNESOTA CODE

• Manual shut-off valve
• Manual pilot valve
• Pilot gas regulator
• Electronic operating control with

remote thermometer

• Adjustable manual reset safety high

limit

• Pressure relief valve (75 PSI)
• Two temperature gauges
• Terminal strip

• 2 amp fuse
• EM

2

- pump time delay (500-1825)

• Power on/off switch
• Power on light
• Non-combustible base

(500-1825 Outdoor)

• Integral pump (500-1825)
• Water flow switch (500-1825)
• Water pressure switch (2000-5000)

• Integral finned copper tube heat

exchanger. ASME 160 lb. working
pressure, 2-pass configuration

• Glass-lined cast iron headers
• Stainless steel burners
• Built-in integral draft hood

(indoor models)

• 115/24V transformer for 24V

control system

• Redundant safety gas valve

Model Nomenclature

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

*Spark Ignition standard on Natural Gas and Propane models (Ignition 09).
**Available as Model 999 for local jurisdictions that limit input to 1,000,000 BTU/h.

M

T

Minnesota Code (MX)

500-850:
• low water cutoff (manual

reset with test button)

• manual firing valve

(2nd shutoff valve)

• 100% lockout
• high gas pressure switch
• additional safety valve

1010-2450:
• low water cutoff (manual

reset with test button)

• manual firing valve

(2nd shutoff valve)

• leak test valve
• 100% lockout
• high & low gas pressure

switches

• solenoid safety valve
• motorized safety with

proof of closure

2800-5000:
• System 4

(see heater pricing)

• low water cutoff (manual

reset with test button)

• manual firing valve

(2nd shutoff valve)

• leak test valve
• 100% lockout
• high & low gas pressure

switches

• motorized safety valve
• motorized safety with

proof of closure

Kentucky Code (KC) (STD)
• 200° F (max.) automatic

reset high limit

• 200° F (max.) manual

reset high limit

LOCATION

I-INDOOR
E-OUTDOOR

Outdoor Units

Standard

Sys. 4

Ship

Size

Unit *

for FM &

Weight

Sys. 9/16/18

Minnesota

lbs.

500

7,693

N/A

855

600

7,900

N/A

949

715

8,153

N/A

1050

850

8,468

N/A

1100

1010**

9,170

N/A

1240

1,200

9,594

N/A

1410

1,430

9,990

N/A

1570

1,670

10,177

N/A

1622

1,825

10,976

N/A

1725

2,200

15,521

18,307

2320

2,800

17,590

20,324

2500

3,200

19,828

22,819

2840

3,600

20,820

23,677

3175

4,000

22,239

26,003

3940

4,500

23,252

27,750

3790

CODE OPTIONS INCLUDE:

CSD - 1 Code (JX)

500-2450:
• low water cutoff

(man. reset w/test button)

• manual firing valve (2nd shutoff valve)
• leak test valve
• 100% lockout

2800-5000:
• low water cutoff

(man. reset w/test button)

• manual firing valve (2nd shutoff valve)
• multiple leak test valves
• 100% lockout
• high & low gas pressure switches

CSD-1 + IRI Code Package (JD)

500-2450
• low water cutoff

(man. reset w/test button

• manual firing valve (2nd shutoff valve)
• leak test valve
• 100% lockout
• normally open vent valve

2800-5000:
• low water cutoff

(man. reset w/test button

• manual firing valve (2nd shutoff valve)
• multiple leak test valves
• 100% lockout
• high + low gas pressure switches
• normally open vent valve

FM Code (FX)

500-2450:
• add CSD-1

2800-5000:
• System 4

(see heater pricing)

• low water cutoff (manual

reset with test button)

• manual firing valve

(2nd shutoff valve)

• multiple leak test valves
• 100% lockout
• high & low gas pressure

switches

• normally open vent valve
• morotized safety valve

California Code (LC)
• order low water cutoff +

100% lockout

Indoor Units

STANDARD

SYS 4

SHIP

SIZE

UNIT*

FOR FM &

WT

SYS 9/16/18

MINNESOTA

lbs.

500

6,622

N/A

808

600

6,888

N/A

819

715

7,061

N/A

873

850

7,505

N/A

945

1010**

7,926

N/A

1041

1,200

8,325

N/A

1199

1,430

8,694

N/A

1280

1,670

9,417

N/A

1445

1,825

9,772

N/A

1570

2,000

13,273

17,055

1950

2,450

14,013

17,993

2100

3050

16,053

19,930

2250

3500

17,858

21,570

2510

4050

19,291

22,361

2750

4500

20,841

26,130

2900

5000

21,832

27,084

3200

Advertising