Model nomenclature, Pennant option descriptions – Pentair 472645 User Manual

Page 6

Advertising
background image

6

• Automatic bypass
• ASME 160 psi working pressure heat

exchanger

• ASME “H” stamp
• Flanged water connections
• Glass-lined cast iron headers
• External header gaskets
• 75 psi (817 kPa) ASME

rated pressure relief valve

• Flow switch
• Temperature and pressure gauge

• Multiple operating gas valve/pressure

regulators

• Manual “A” gas valve
• Intake air filter
• Multiple, removable burner trays
• Stainless steel burners
• Built-in draft fan(s) for Category I or III

venting

• Air pressure switch
• Burner site glass
• 24V control system

• 115/24VAC 75VA power from class 2

transformer

• Manual reset high limit
• Automatic reset high limit
• Electronic PID temperature control with

LCD and touchpad

• PC board for electrical connections
• Hot surface ignition
• On/Off toggle switch
• Pump time delay
• Diagnostic lights
• Convertible indoor or outdoor operation
• Bronze trim

Standard Features PowerMax PM (500-2000)

Model Nomenclature

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

P

M

P

A

C

C

2

N

SERIES

PM =

POWERMAX

OPTIONS

X-STANDARD
J-CDS-1, IRI
L-MN (indoor)

ALTITUDE

0-10,000 ft

FIRING MODE

C- ON/OFF

LOCATION

C- INDOOR
OUTDOOR

FUEL

N-NATURAL
P-PROPANE

PUMP

N-NORMAL

SIZE

MBTU/h

0 5 0 0
0 7 5 0
1 0 0 0
1 2 5 0
1 5 0 0
1 7 5 0
2 0 0 0

HEAT EXCHANGER

B- GLASS LINED CAST IRON / COPPER /

BRONZE TRIM (Std)

K- BRONZE / COPPER
P- GLASS LINED CAST IRON / CuNi /

BRONZE TRIM

S- BRONZE / Cu-Ni

APPLICATION

P- POOL

REVISION

2- SECOND

Pennant Option Descriptions

Code option J: for CSD-1, FM, IL (low water cutoff not included)
The changes made to the standard Pennant to achieve code option J are as follows:

•

Adds manual reset high and low gas pressure switches

•

Adds gas regulator

•

Changes ignition control from the standard three-attempt to a single attempt

Kit for IRI:
This kit is added to a Pennant unit with code option J. In total, code option J with the IRI kit:

•

Adds manual reset high and low gas pressure switches

•

Adds safety valve with gas regulator

•

Adds leak test valve for additonal safety

•

Adds normally open vent valve

•

Changes ignition control from the standard three-attempt to a single attempt

Code option L: for MN and LDS
Sizes 500 to 1000:

Sizes 1250 to 2000:

•

Adds safety valve with regulator

•

Adds solenoid safety valve

•

Adds high gas pressure switch

•

Adds motorized safety valve with proof of closure

•

Adds leak test valve

•

Adds leak test valve

•

Adds high and low gas pressure switches

Advertising