u

Black Level Setting [Pedestal: –30 - +30]

The black level (pedestal) of the luminance (Y) sig-
nal can be set. Used in adjusting the black levels
of two or more cameras.

i

Contrast Adjustment [Contrast (Gamma):
LOW/MID/HIGH]

Contrast can be adjusted to any of three levels.

o

Chroma Level Adjustment
[Chroma Level: –3 - +3]

Chroma Level can be decreased or increased to
any of three levels each.

!0

Skin Color Adjustment [Flesh Tone: –3 - +3]

Skin color can be decreased or increased to any of
three levels each.

!1

White Balance Setting [White Bal: ATW/AWC A/
AWC B/P SET 3 200K/P SET 5 600K]
ATW:

The white balance is automatically adjusted

to be always right.

AWC A, AWC B:

Once the white balance is adjust-

ed with the ITEM/AWC switch on the back of the
camera, it is no longer necessary to set the
white balance again if you simply select AWC A
or AWC B, provided that the camera is used
under the same conditions.

Fine color adjustment can be made after setting
AWC by red/blue gain adjustment in user mode
or from the RCU (RCB).

P SET 3 200K:

The white balance is adjusted to

3 200K illumination.

P SET 5 600K:

The white balance is adjusted to

5 600K illumination.

!2

Highlight Chroma Setting [Highlight Chroma:
OFF/LOW/HIGH]

At LOW or HIGH, the color dynamic range widens
to prevent highlighted white portions from suppres-
sion.

!3

Horizontal Phase Adjustment
[H Phase: –206 - +49]

Horizontal phase can be adjusted when a genlock
signal is supplied.

Neither P SET 3 200K nor P SET 5 600K can be set
from the RCU (RCB) or the hybrid control panel.

Note