@0

Flesh Noise Suppress Level Setting [Flesh Noise
Suppress: OFF/LOW/HIGH]

Flesh noise is suppressed in two steps when the
DTL Level is at HIGH or LOW.

@1

Electronic Shutter Setting [Shutter Speed:
OFF/1/100 to 1/10 000/S/Scan/Auto ND]
OFF:

Electronic shutter is turned off.

1/100, 1/250, 1/500, 1/1 000, 1/2 000, 1/4 000, 1/10 000:

Electronic shutter operates at one of these
speeds as selected.

S/Scan (Synchro Scan):

Electronic shutter oper-

ates at the speed set with the electronic shutter
synchro-scan setting

@2.

Auto ND:

Electronic shutter is controlled to auto-

matically adjust the luminance. (ELC)

@2

Electronic Shutter Synchro Scan Setting
[Synchro Scan: 60.58Hz - 15.75kHz]

This setting is possible only when Electronic Shutter
setting

@1 is at S/Scan.

Horizontal bar noise can be reduced by synchro-
scan adjustment in shooting workstation scenes, for
example.

• In case of using the RCU (RCB), none of the

shutter speeds

1/250, 1/2 000, 1/4 000, and

1/10 000 can be selected.

• In case of using the hybrid control panel, only

OFF, 1/100, or Auto ND (ELC) can be selected.

• If the lens iris switch is at M (Manual) when oper-

ating the camera alone or when the iris switch
on the RCU (RCB) is at AUTO, Auto ND may not
function. Set the lens iris switch to A (Auto).

• Flickering may increase at Auto ND under fluo-

rescent lights.

• Auto ND is automatically selected if Auto ND

(ELC) setting

r is set to ON.